background image

1/4'' FPT

WATER LINE

CONNECTION

1'' FPT

EACH END

OF MANIFOLD

1'' CONDUIT

CONNECTION

14

(356)

14

(356)

6 1/4

(159)

18

(457)

2 1/4

(57)

57 1/2
(1460)

30 9/16

(776)

7 3/4

(197)

1 3/4

(44)

9 3/4
(248)

1 PHASE

3 PHASE

8 AWB Cu
8 AWB Cu

INSTALLATION INSTRUCTIONS

TO PLUMB:

1. A drain manifold complete with valve is supplied on all Model

'TDM' units. Location of valve handle is at the discretion of the

fabricator (see drawing).

2. Connect 1'' drain connection to a suitable drain line.

3. Connect 1/4 NPT water supply to the Solenoid valve in the

Outlet Box. NOTE: Maximum water pressure is 120 psi and

maximum temperature is 120

°

F. A backflow prevention valve is

installed in the water fill system. Check local codes for any

additional plumbing requirements.

TO WIRE:

1. Final connection is accomplished by bringing proper power

supply leads (see 'WIRING REQUIREMENTS label') through 1''

conduit knockout to terminal block supplied within the Master

Control Panel. Check nameplates for voltage and phase.

NOTE: INSTALLATION MUST MEET LOCAL PLUMBING AND

ELECTRICAL CODES.

300748-3   REV (-)

INSTALLATION INSTRUCTIONS

BUILT-IN MODULAR WARMERS

MOD 427TDM/AF (2 CONTROL PANELS)

WELLS/BLOOMFIELD * VERDI, NV

ELECTRICAL

MODEL

VOLTS

WATTS

AMPS PER LINE 3 PHASE

SINGLE

TEMP.

FIELD WIRING GAUGE

RATING

MOD-427TDM
MOD-427TDM

240

208

4960
6600

14.5
17.8

27.5

23.8

12 AWB Cu
10 AWB Cu

75

°

C

75

°

C

CUTOUT DETAILS

PRODUCT DIMENSIONS

NOTE: MOD-427TDM/AF UNITS ARE SHIPPED THREE PHASE

AND ARE FIELD CONVERTIBLE TO SINGLE PHASE. THE

DRAIN MANIFOLD WITH 1 INCH INTERNAL FPT IS SUPPLIED

WITH THE UNIT.

INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY

OUTLINED BELOW UPON INSTALLATION:

1. Required Installation Clearances:

Wooden and Metal Installation: DO NOT install closer than

6 inches to front wall, 1 inch to back and side walls,

and 6 3/4 inches to surface below the unit.

2. Unit shall be accessible for servicing from the bottom.

3. If storage is to be used underneath the unit, it is

recommended that a baffle be placed 8 1/2 inches below

the unit to avoid contact with elevated temperatures.

TO FABRICATE:

1. Lay out "cutout" dimensions on countertop and front

apron.

2. Lay out and fabricate control panel holes in counter

apron using the control box as a template.

3. Cut out holes.

TO INSTALL:

IMPORTANT - DO NOT disconnect lead wires from the

Master Control Panel when making installation.

1. Tilt and pass Control Panel and electrical box through

the countertop cutout, then through the apron cutout.

Lower modular section into countertop cutout and position.

RECOMMENDATION: Before final seating of modular section

to countertop, apply a bead of silicone adhesive/sealant to

the supplied gray gasket material on the underside of the

mounting flange.

2. From underneath, insert screwdriver into slots in the

Wellslock frame and twist the ears outward (clockwise) as

required to secure flange tightly to countertop.

3. Mount Control Box to apron cutout as shown in drawing.

4. Mount Control Panel onto the electrical box using the

screws supplied.

5. Remove any excess gasket or sealant material from the

outer flange.

CLEARANCES

BACK

SIDE

BOTTOM

FRONT

(25)

1

1

(25)

(171)

6 3/4

(152)

6

MINIMUM CLEARANCE REQUIRED

 FROM UNIT TO THE NEAREST SURFACE

L1

L2

L3

14.5
17.8

9.8

11.3

AMPS

PHASE

TOP CUTOUT

FRONT PANEL CUTOUTS

12 7/8

(327)

56 3/4

(1441)

29 1/2

(749)

16 7/8

(429)

5

(127)

3 1/8

(79)

6

(152)

3 1/8

(79)

5

(127)

FLANGE

GASKET

WELLSLOK

COUNTERTOP

SCREWDRIVER

OUTLET BOX

SOLENOID

WATER SUPPLY

1/4 NPT

MASTER

CONTROL

PANEL

IMPORTANT:

MOUNT APPLIANCE SO THAT THE

CONTROL PANEL IS LOCATED TO

THE FRONT OF THE FIXTURE.

WITH AUTO WATER FILL

INCHES

(MM)

Отзывы: