Figure 9 - “RF Output” Tab - Full View
NOTE: The RF Input and TS List are available for view and search on the left side for ease of operation and setup.
The following parameters are Global Configurations for RF Output (Figure 9a):
Output Level:
Allows the user to set the combined RF Output
Level. The range is 30 to 45 dBmV. The recommended output
level is 40 dBmV.
Output Mode:
Allows the user to set the Output Mode. For
normal operation the output mode should be set to QAM256B.
CW is only used for testing and measuring level. (Options:
QAM256B, QAM 64B, or CW)
1
2
Output Ch Map: Allows the user to set the Output Channel Map. Options are: STD, HRC, and IRC. (Factory Default: “STD”)
3
Figure 9a - “Add Output Streams Configuration”
1
2
3
Remember to click on the SAVE button to apply the new values/configurations.
IMPORTANT: All channels must be set within a 768 MHz span.
The following parameters are configurations for each RF Outputs 1 to 8 (Figure 9b):
Output Enable: Allows the user to turn the RF Output “On”
or “Off”.
Output Ch/Freq:
Allows the user to set the Channel/Frequency.
The range is channel 2 to 158.
Assigned TS:
Allows the user to assign any transport stream
to RF output from the dropdown.
1
2
3
Figure 9b - “Add Output Streams Configuration”
1
2
3
Section 9 – RF Output
The “RF Output” tab (Figure 9) on the main navigation menu allows the user to select transports for each of up to 8 QAM
outputs.
NOTE:
Clicking the small arrow ( collapsed; expanded) beside each program will show or hide read-only data.