Over The Range Convection Microwave Oven / Installation Manual
24 / 63 EN
5
Installation
B2. Remove blower plate
Remove and save the screw that holds the blower
plate to the microwave. Lift off the blower plate.
Back of
Microwave
Blower Plate
B3. Attach the mounting plate to the
wall
Attach the plate to the wall using toggle bolts. At
least one wood screw must be used to attach the
plate to a wall stud.
1. Remove the toggle wings from the bolts.
2. Insert the bolts into the mounting plate through
the holes designated to go into drywall and
reattach the toggle wings to 3⁄4” (19 mm) onto
each bolt.
To use toggle bolts
Wall
Mounting
Plate
Spacing for Toggles More
Than Wall Thickness
Toggle
Bolt
Toggle Wings
Bolt End
3. Place the mounting plate against the wall and
insert the toggle wings into the holes in the wall
to mount the plate.
C
Before tightening toggle bolts and
wood screw, make sure the tabs on
the mounting plate touch the bot-
tom of the cabinet when pushed
flush against the wall and that the
plate is properly centered under the
cabinet.
A
Be careful to avoid pinching fingers
between the back of the mounting
plate and the wall.
4. Tighten all bolts. Pull the plate away from the
wall to help tighten the bolts.
B4. Use top cabinet template for
preparation of top cabinet
You need to drill holes for the top support screws
and a hole large enough for the power cord to fit
through.
•
Read the instructions on the TOP CABINET
TEMPLATE.
•
Tape it underneath the top cabinet.
•
Drill the holes, following the instructions on the
TOP CABINET TEMPLATE.
A
Wear safety goggles when drilling
holes in the cabinet bottom.