INSTALLATION

Installation Instructions

PLUMBING CONNECTIONS

   WARNING

Plumbing connections must comply with ap-

plicable sanitary, safety and plumbing codes.

The water supply inlets are provided with 3/8” (10 mm) 

compression fittings for 3/8” O.D. copper tubing. The wa

-

ter supply line pressure should be 25 - 50 psi (170 - 345 

kPa) for each line. The water supply to the generator tank 

is separate from the water supply to the cooling system 

where steam is condensed before entering the drain line.

Install line strainers (not provided). A manual shutoff valve 

for each supply line must be provided convenient to the 

steamer.
Treated water feeding the boiler inlet supply is recom-

mended, and untreated water feeding the condensing 

water inlet. Hook-ups are labelled on the back of the 

steamer.
10 pan units are provided with an adjustable condensing 

water valve. It has been factory set to 2-1/2 turns open, 

that will suit most installations. Adjust as required to suit 

local water inlet temperature and pressure. Turn screw 

clockwise  to  decrease  flow  or  counterclockwise  to  in

-

crease flow.

DRAIN CONNECTIONS

   CAUTION

In order to avoid any back pressure in the 

steamer, do not connect solidly to any drain 

connection.

The drain connection must be 1½” IPS down, preferably 

with one elbow only, maximum length of 2 feet horizontal 

before open air gap and piped to an open air gap type 

drain. Drain pipe should be copper. DO NOT use PVC 

pipe - PVC pipe may lose its rigidity or glue may fail.

Adjusting Screw

Figure 3 

WATER QUALITY

The water supply connected to this steamer should con-

tain no more than 2.0 grains of hardness per gallon with 

pH from 7.0 to 8.5. This degree of hardness and pH can 

easily be obtained with the use of a properly maintained 

water softener.
Water supplies vary from one location to another. A local 

water treatment specialist should be consulted before in-

stalling any steam generating equipment.
Untreated water contains scale producing minerals which 

can precipitate onto the surfaces in the boiler. Due to the 

temperatures in the boiler, the minerals can bake onto the 

surfaces and components. This can result in early compo-

nent failure and reduced product life.
Mineral scale on components causes several problems:
1.  The surfaces of the heating devices become coated 

with scale, reducing the heat transfer efficiency. This 

can produce hot spots on the heating elements and 

result in premature failure.

2.  The water level probes become coated with scale. 

Scale will bridge across the probe insulator from the 

metal extension which senses the water level in the 

boiler cell. Once this scale becomes wet, the water 

level control is unable to maintain the proper water 

level in the boiler. This situation may cause an electric 

heating element to fail if the element is not adequate-

ly covered by water.

Strainers and filters will NOT remove minerals from the 

water.
Refer to REMOVAL OF LIME SCALE DEPOSITS, in this 

manual.

Содержание SN-3E

Страница 1: ...COUNTER CONVECTION STEAMER INSTALLATION OPERATION MAINTENANCE 42 Allen Martin Drive Essex Junction Vermont 05452 USA Telephone 802 658 6600 Fax 802 864 0183 www blodgett PN S00059 Rev E 8 18 2018 G S...

Страница 2: ...Your Service Agency s Address Model Serial number Steamer installed by Installation checked by...

Страница 3: ...o Not Come On 13 Unit Shuts Down While in Operation 13 IMPORTANT WARNING Improper installa tion adjustment alternation service or maintenance can cause property damage in jury or death Read the instal...

Страница 4: ...IONS Drain 1 25mm IPS piped to open floor drain No solid connection 24 length before open air opening no bends or elbows Cold Water 3 8 10mm tubing at 25 50 PSI 170 345 kPa The drain piping must consi...

Страница 5: ...optional 4 adjustable legs are used remove the four levelling feet on the bottom of the steamer FEET Levelling Feet standard or 4 Adjustable Legs Op tional Thread the four 2 levelling feet shipped in...

Страница 6: ...ype drain Drain pipe should be copper DO NOT use PVC pipe PVC pipe may lose its rigidity or glue may fail Adjusting Screw Figure 3 WATER QUALITY The water supply connected to this steamer should con t...

Страница 7: ...echanical connec tions have been made thoroughly test the steamer before operation 1 Check that proper water drain and electrical connec tions have been made 2 Turn main power switch ON After approxim...

Страница 8: ...At the end of the cooking cycle the COOKING light goes off the buzzer sounds and steam stops being supplied to the cooking chamber To stop the buzzer turn the timer to OFF SHUTDOWN Turn the main power...

Страница 9: ...lly thaw overnight in a refrigerator This will reduce their cooking time PREPARATION Prepare vegetables fruits meats seafood and poultry normally by cleaning separating cutting removing stems etc Cook...

Страница 10: ...lid pan cover pasta with cold water Spaghetti Regular Vermicelli Macaroni Shells Elbows Noodles wide Lasagna Noodles 12 15 15 18 12 15 15 18 Frozen Casseroles Lasagna 35 Full Pan Meat Loaf 3 5 pounds...

Страница 11: ...1 6 Cut 8 5 lb Carrots Baby Whole Frozen Crinkle Cut Frozen Sliced Fresh 8 7 8 11 7 lb 4 lb 9 lb Cauliflower Florets Frozen Fresh 6 7 8 6 7 8 Celery 1 Diagonal Cut 7 5 lb Corn Yellow Whole Kernel Fro...

Страница 12: ...water with a cloth or sponge to clean exposed bead of door gasket rinse with warm clear water and wipe with a dry cloth 5 Wipe surfaces which touch door gasket with a cloth or sponge and warm soapy w...

Страница 13: ...ces of lime that will not flush out drain Should the tank cover have to be removed check condi tion of sealing gasket before replacing cover The hold down bolts are to be tightened to 160 inch pound t...

Страница 14: ...hrenheit just below water boiling point Howev er for high altitude locations an authorized servicer must adjust the steamer temperature lower To adjust 1 Remove side panel and turn control panel power...

Страница 15: ...probes check visually and clean or chip off scalant Replace probe This problem is an indication of severe harmful water conditions which should be corrected immediately to avoid damage to the componen...

Отзывы: