background image

1

SC-GH SERIES

HIGH EFFICIENCY GAS FIRED CONVECTION STEAMER

INSTALLATION – OPERATION 

 MAINTENANCE

BLODGETT OVEN COMPANY

www.blodgett.com

44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone (800) 331-5842, (802) 860-3700 Fax: (802) 864-0183

S00061 Rev B (2/05)

Содержание SC-10GH

Страница 1: ...ENCY GAS FIRED CONVECTION STEAMER INSTALLATION OPERATION MAINTENANCE BLODGETT OVEN COMPANY www blodgett com 44 Lakeside Avenue Burlington Vermont 05401 USA Telephone 800 331 5842 802 860 3700 Fax 802...

Страница 2: ...ity of this or any other appliance PURCHASER Instructions to be followed in the event that the operator of this appliance smells gas must be posted in a prominent location This information shall be ob...

Страница 3: ...TABLE OF CONTENTS DESCRIPTION PAGE 1 0 Service Connections 4 2 0 Installation 5 3 0 Performance Check 11 4 0 Operation Instructions 12 5 0 Maintenance 14 6 0 Deliming Procedure 19 7 0 Troubleshooting...

Страница 4: ...ER 3 8 O D tubing at 25 50 PSI 170 345 kPa GENERATOR WATER 3 8 O D tubing at 25 50 PSI 170 345 kPa Less than 1 5 PPM Less than 13 PPM Less than 20 PPM Less than 60 PPM WATER QUALITY STATEMENT FOR GENE...

Страница 5: ...he gas supply piping system at test pressures equal to or less than psi 3 5 kPa Electrical grounding must be provided in accordance with local codes or in the absence of local codes with the National...

Страница 6: ...approximately equal to the fan area will relieve such vacuum In case of unsatisfactory performance on any appliance check with the exhaust fan in the OFF position 2 2 WALL EXHAUST FAN The exhaust fan...

Страница 7: ...connect device that complies with the standard for quick disconnect devices for use with gas fuel ANSI Z21 41 CSA 6 9 adequate means must be provided to limit the movement of the appliance without dep...

Страница 8: ...its operating simultaneously the manifold pressure on all units should not show any appreciable drop Fluctuations of more that 25 on natural gas and 10 on propane gas will create problems affecting bu...

Страница 9: ...vents itself by the negative pressure created by the condensate water drainage This negative pressure prevents steam leakage around the door gasket and helps draw the steam through the cooking compar...

Страница 10: ...may void the warranty Untreated water contains scale producing minerals which can precipitate onto the surfaces in the steam generator Due to the temperatures in the steam generator the minerals can b...

Страница 11: ...ing the compartment after about 45 seconds 6 After five minutes of operation check drain line to ensure that water from the cold water condenser is flowing through the drain line 7 Open compartment do...

Страница 12: ...until the ready light comes on 5 Cooker is now ready for use Your steamer has been factory set when ON to maintain water temperature during the READY phase at approximately 205 Fahrenheit 97 Celsius j...

Страница 13: ...equipped with a removable drain screen Frequently check the drain screen for accumulation of food particles Should food particles accumulate against or clog the drain screen remove it clean it thoroug...

Страница 14: ...e serving Steam cooking should be carefully time controlled Keep holding time of hot food to a minimum to produce the most appetizing results Prepare small batches cook only enough to start serving th...

Страница 15: ...juices do not need to be preserved Solid pans are good for cooking puddings rice and hot breakfast cereals Vegetables and fruits are cooked in solid pans in their own juices Meats and poultry are coo...

Страница 16: ...artment interior with clean water 4 Use warm soapy water with a cloth or sponge to clean exposed bead of door gasket rinse with warm clear water and wipe with a dry cloth Wipe surfaces which touch doo...

Страница 17: ...water into electric controls Following daily and period maintenance procedures will enhance the long life for your equipment Climactic conditions salt air may require more thorough and frequent cleani...

Страница 18: ...the area has been subjected to excessive heat These darkened areas are caused by thickening of the protective surface of the stainless steel and are not harmful Heat tint can normally be removed by th...

Страница 19: ...o OFF to flush generator Repeat this step three times to completely flush generator 6 Clean exterior and interior Use a mild solution of soap and water Rinse with clean water Dry with a soft cloth LEA...

Страница 20: ...gas supply 3 Incorrect pressure at supply Water flows into cooking compartment 1 Short circuit between operating level probe and body inside steam generator 2 Excessive scale build up on operating pro...

Страница 21: ...te valve does not close Check thermostatic cooling valve body for foreign particles or damage Water not being supplied to steam generator 1 Water supply is OFF 2 Supply water pressure too low 3 Defect...