BCX, BX MENUSELECT CONTROL
Service Level Programming
(The oven needs to be in the “ON” position)
Prog
Cooling Fan Probe Temp
1
Quench
Probe Temp
4
Core Probe Temp
7
Boiler Probe Temp
Steam
Water Hi Level SW
Steam on Demand
Water Low Level SW
“Press the Dial to Exit”
Scroll to Exit
Press the Dial to Exit
Scroll to Exit Press (“Dial”)
Factory Level Programming
(The oven needs to be in the “ON” position)
Press the Maint Key
Scroll to Factory Program
Press the Dial to Enter
Enter the Factory Code “3228”
Press the Dial to Enter
Scroll to “Appliance Type”
Press the Dial to Enter
Turn Dial to set Gas or Electric
Press the Dial to Enter
Scroll to “Cavity Probe Offset”
Press the Dial to Enter
Turn the Dial to Set the Offset
Press the Dial to Enter
Scroll to ”Core Probe Offset”
Press the Dial to Enter
Turn the Dial to set the Offset
Press the Dial to Enter
Scroll to Exit
Press the Dial to Exit
Scroll to Exit again
Press the Dial to Exit the
Program Level.