SHORT FORM SPECIFICATIONS:
Provide Blodgett Combi model BCX-14G single, gas combination-oven/steamer. Unit shall have the ability to cook with pressureless steam (212F),
hot air, or combination of steam and hot air (with an operating range 140F to 500F), vario-steaming (operating range 140F to 212F), low temperature cooking and holding, rethermal-
izing, cool down mode and our Exclusive Steam on Demand steam injection system. Unit shall have programmable manual control capable of storing 100 recipes and USB connection.
Oven capacity to accept 7ea 18x26 bake pans or 14ea 12x20x2.5” full size steam table pans with 3-1/4” spacing. Front access service user interface control panel and service diagnosis
system. Unit shall be constructed with a fully welded stainless steel frame. Cooking chamber shall be constructed with 304 series with bright-annealed stainless steel finish and coved
corners. Retractable hose reel (excluding top sections) to include front water shut off valve. Unit shall include a four speed, bi-directional fan with vent switch to control humidity in
the cooking chamber. Dual pane thermal glass window with 180 degree door swing, two-step safety door-latch with adjustable door hinges, door mounted drip pan. Unit to include
a detachable 4” core temperature probe and halogen lights. Supply with exclusive time to delime indicator with adjustable settings of 30, 60 or 90 hours of run time, semi-automatic
deliming system. Where applicable, quantities in this spec are doubled for stacked units. A start-up inspection service will be performed by our factory-authorized agent at no cost to
the operator. One-year parts and labor warranty, standard.
GAS SUPPLY
(per section)
:
3/4” NPT
Inlet Pressure:
Natural - 7.0” W.C. static to unit Propane - 14.0” W.C. static to unit
Maximum Input:
Hot Air - 65,000 BTU/hr Boiler - 50,000 BTU/hr Total Input - 115,000 BTU/hr
WATER SUPPLY & DRAIN:
Good quality water feed is the responsibility of the owner. Water quality must be within
the following general guidelines.
TDS: 40-125 ppm
Hardness: 35-100 ppm
pH: 7.0 - 8.5
Silica: <13 ppm
Chlorides: <25 ppm
Chlorine: <0.2 ppm
Chloramine: <0.2 ppm
The best defense against poor water quality is a water treatment system designed to
meet your water quality conditions. Blodgett offers optional systems from Optipure.
Pressure:
40(min)-50(max) PSI
Connections:
2” drain connection - max. drain temperature 140°F (60°C)
3/4” garden hose cold water
The drain piping must consist of temperature resistant material, greater than 160°F, and
be of adequate diameter not to cause flow restriction. Improper materials may deform
and cause restrictions, thus affecting performance.
Appliance is to be installed with backflow protection in accordance with federal, state or
local codes.
SHIPPING INFORMATION:
Approx. Weight:
Single - 645 lbs. (293 kg) Double - 1320 lbs. (599 kg) Stand w/guides - 140 lbs. (64 kg)
Crate sizes (per section):
44.5” H x 42” W x 54.25” D (1130 x 1067 x 1378mm)
DIMENSIONS:
Floor space:
42.30” x 40.19” (1074 x 1021mm)
Unit Height:
Single
36.16” (919mm)
Double
69.22” (1758mm) without casters/legs
Additional Height:
Low profile caster for stacked units 4” (101.6mm)
6” adjustable legs
6.88” - 8” (174.6-203.2mm)
6” adjustable seismic legs
6.63” - 8” (168.3-203.2mm)
25” adjustable legs
25.25” - 26.38” (641.4-670mm)
Stand w/rack supports
22.5” - 23.63” (571.5-600.1mm)
Stand w/rack supports on casters
22.63” (574.7mm)
OVEN CLEARANCES:
Right Side
1” (25.4mm)
Left Side
6” (152.4mm)
Rear
6” (152.4mm)
MINIMUM ENTRY CLEARANCE:
Uncrated
33” (838mm) after adjustment of flue brackets
Crated
42” (1066.8mm)
POWER SUPPLY
(per section):
Standard
115VAC, 12 amp, Nema 5-20R dedicated receptacle
Option
208-240VAC, 6 amp, Nema 6-15 dedicated receptacle
Export
Export voltages available on request
Blodgett recommends a Pass & Seymour, model 2097, GFCI due to the
use of a variable frequency drive. Must be hard wired in some cases.
NOTE:
The company reserves the right to make substitutions of components
without prior notice
DIMENSIONS ARE IN INCHES (MM)
0 (0)
5.00 (127)
2.31 (59)
3.00 (76)
33.06 (840)
35.37 (898)
36.06 (916)
38.06 (967)
66.12 (1679)
69.22 (1758)
0(0)
5.59 (142)
23.59 (599)
40.16 (1020)
2.59 (66)
F
U
F
U
REAR VIEW
U
D
D
D
REAR VIEW
0 (0)
3.00 (76)
5.00 (127)
2.31 (59)
33.06 (840)
36.16 (919)
0 (0)
2.59 (66)
5.59 (142)
23.59 (599)
F
U
F
U
40.16 (1020)
D
D
0 (0)
72.7 (1848)
43.3 (1100)
Front of oven
with door closed
TOP VIEW
F
U
Unfiltered Water - Condensate, cold only
Filtered Water - Boiler, hot or cold
D
Electric
Drain
Gas
117
11
7
Содержание BCX-14G
Страница 65: ...EŽƚĞƐ 65 ...
Страница 68: ...1 68 ...
Страница 70: ...3 70 ...
Страница 71: ...4 71 ...
Страница 72: ...5 72 ...
Страница 73: ...6 73 ...
Страница 74: ...7 74 ...
Страница 75: ...8 I 75 ...
Страница 76: ...9 y I i w II VA w ti m dul will non 76 ...
Страница 78: ...11 If t r t n 4 th modul 100 nd th pll t r m lnln 78 ...
Страница 84: ...50 0 235 Volts AC 3Ø 2 7 Amps Forward 84 ...
Страница 85: ...50 0 235 Volts AC 3Ø 2 7 Amps Reverse 85 ...
Страница 109: ...EŽƚĞƐ 109 ...
Страница 112: ...112 ...
Страница 113: ...113 ...