BLODGETT OVEN COMPANY
www.blodgett.com
• 44 Lakeside Avenue, Burlington, VT 05401 • Phone: (802) 658-6600 • Fax: (802) 864-0183
BCX-14E
Printed in U.S.A.
NOTE:
FOR COMMERCIAL USE ONLY
APPROVAL/STAMP
P/N R11548 Rev Z (7/17)
SHORT FORM SPECIFICATIONS:
Provide Blodgett Combi model BCX-14E single, electric combination-oven/steamer. Unit shall have the ability to cook with pressureless steam
(212F), hot air, or combination of steam and hot air (with an operating range 140F to 500F), vario-steaming (operating range 140F to 212F), low temperature cooking and holding,
rethermalizing, cool down mode and our Exclusive Steam on Demand steam injection system. Unit shall have programmable manual control capable of storing 100 recipes and USB
connection. Oven capacity to accept 7ea 18x26 bake pans or 14ea 12x20x2.5” full size steam table pans with 3-1/4” spacing. Front access service user interface control panel and
service diagnosis system. Unit shall be constructed with a fully welded stainless steel frame. Cooking chamber shall be constructed with 304 series with bright-annealed stainless steel
finish and coved corners. Retractable hose reel (excluding top sections) to include front water shut off valve. Unit shall include a four speed, bi-directional fan with vent switch to control
humidity in the cooking chamber. Dual pane thermal glass window with 180 degree door swing, two-step safety door-latch with adjustable door hinges, door mounted drip pan. Unit to
include a detachable core temperature probe and halogen lights. Supply with exclusive time to delime indicator with adjustable settings of 30, 60 or 90 hours of run time, semi-automatic
deliming system. Where applicable, quantities in this spec are doubled for stacked units. A start-up inspection service will be performed by our factory-authorized agent at no cost to
the operator. One-year parts and labor warranty, standard.
WATER SUPPLY & DRAIN:
Good quality water feed is the responsibility of the owner. Water quality must be within the
following general guidelines.
TDS: 40-125 ppm
Hardness: 35-100 ppm
pH: 7.0 - 8.5
Silica: <13 ppm
Chlorides: <25 ppm
Chlorine: <0.2 ppm
Chloramine: <0.2 ppm
The best defense against poor water quality is a water treatment system designed to meet
your water quality conditions. Blodgett offers optional systems from Optipure.
Pressure:
40(min)-50(max) PSI
Connections:
2” drain connection - max. drain temperature 140°F (60°C)
3/4” garden hose cold water
The drain piping must consist of temperature resistant material, greater than 160°F, and
be of adequate diameter not to cause flow restriction. Improper materials may deform and
cause restrictions, thus affecting performance.
Appliance is to be installed with backflow protection in accordance with federal, state or
local codes.
SHIPPING INFORMATION:
Approx. Weight:
Single section
620 lbs. (281 kg)
Double stack
1260 lbs. (571 kg)
Stand w/guides
140 lbs. (64 kg)
Crate size (per section):
44.5” H x 42” W x 54.5” D (1130 x 1067 x 1384mm)
DIMENSIONS:
Floor space:
42.30” x 40.19” (1074 x 1021mm)
Unit Height:
Single
35.99” (914mm)
Double
68.98” (1752mm) without caster/legs
Additional Height:
6” adjustable legs
6.88” - 8” (174.6-203.2mm)
6” adjustable seismic legs
6.63” - 8” (168.3-203.2mm)
25” adjustable legs
25.25” - 26.38” (641.4-670mm)
Low profile caster
4” (101.6mm)
Stand w/rack supports
22.5” - 23.63” (571.5-600.1mm)
Stand w/rack supports on casters 22.63” (574.7mm)
OVEN CLEARANCES:
Right Side
2” (50.8mm)
Left Side
2” (50.8mm)
Rear
3” (76.2mm)
MINIMUM ENTRY CLEARANCE:
Uncrated
33” (838mm)
Crated
42” (1066.8mm)
POWER SUPPLY
(per section)
:
208VAC
19.0 kW
3 phase (53 amp)
240VAC
19.0 kW
3 phase (46 amp)
480VAC
19.0 kW
3 phase (23 amp)
DIMENSIONS ARE IN INCHES (MM)
REAR VIEW Single
0 ( 0 )
2.91 (74)
5.65 (144)
1.56 (40)
32.99 (838)
0 (0)
3.34 (85)
5.84 (148)
23.59 (599)
F
U
D
D
F
U
35.99 (914)
REAR VIEW
Double Stack
0 ( 0 )
2.91 (74)
5.65 (144)
1.56 (40)
32.99 (838)
0 (0)
3.34 (85)
5.84 (148)
23.59 (599)
F
U
D
D
F
U
68.95 (1752)
65.98 (1676)
35.9 (912)
38.64 (982)
34.55 (878)
40.19 (1021)
D
F
U
F
U
Unfiltered Water -
Condensate, cold only
Filtered Water -
Boiler, hot or cold
D
Electric
Drain
0 [0]
SIDE VIEW
Single or Double
43.3 [1100]
Front of
oven with
door closed
72.8 [1848]
NOTE:
The company reserves the right to make substitutions of components without prior notice
115
Содержание BCX-14G
Страница 65: ...EŽƚĞƐ 65 ...
Страница 68: ...1 68 ...
Страница 70: ...3 70 ...
Страница 71: ...4 71 ...
Страница 72: ...5 72 ...
Страница 73: ...6 73 ...
Страница 74: ...7 74 ...
Страница 75: ...8 I 75 ...
Страница 76: ...9 y I i w II VA w ti m dul will non 76 ...
Страница 78: ...11 If t r t n 4 th modul 100 nd th pll t r m lnln 78 ...
Страница 84: ...50 0 235 Volts AC 3Ø 2 7 Amps Forward 84 ...
Страница 85: ...50 0 235 Volts AC 3Ø 2 7 Amps Reverse 85 ...
Страница 109: ...EŽƚĞƐ 109 ...
Страница 112: ...112 ...
Страница 113: ...113 ...