PRESS
STORED FAULT CODES
PRESS
FUNC
d
0
1
Ÿ
keep pushing until
d
0
8
FUNC
once
E
?
?
Record Code
FUNC
once
d
0
8
Ÿ
keep pushing until
d
0
9
FUNC
once
E
?
?
Record Code
FUNC
once
d
0
9
ź
keep pushing until
d
0
1
FUNC
once
0.
0
COMPLETED
Motor Inverter Error Codes
E_01
Over current event while at constant speed
E_02
Over current event during deceleration
E_03
Over current event during acceleration
E_04
Over current event during other conditions
E_05
Overload protection
E_07
Over-voltage protection
E_08
EEPROM error
E_09
Under-voltage error
E_11
CPU error
E_22
CPU error
E_12
External trip
E_13
USP
E_14
Groung Fault
E_15
Input over-voltage
E_21
Inverter thermal trip
E_35
Thermistor
BX / BCX Man Control - Stored Fault Codes for 50816 Inverter Drive
NOTE: Oven connected to power, mode switch in "OFF" position, display should read " 0.0".
DISPLAY
DISPLAY
111
Содержание BCX-14G
Страница 65: ...EŽƚĞƐ 65 ...
Страница 68: ...1 68 ...
Страница 70: ...3 70 ...
Страница 71: ...4 71 ...
Страница 72: ...5 72 ...
Страница 73: ...6 73 ...
Страница 74: ...7 74 ...
Страница 75: ...8 I 75 ...
Страница 76: ...9 y I i w II VA w ti m dul will non 76 ...
Страница 78: ...11 If t r t n 4 th modul 100 nd th pll t r m lnln 78 ...
Страница 84: ...50 0 235 Volts AC 3Ø 2 7 Amps Forward 84 ...
Страница 85: ...50 0 235 Volts AC 3Ø 2 7 Amps Reverse 85 ...
Страница 109: ...EŽƚĞƐ 109 ...
Страница 112: ...112 ...
Страница 113: ...113 ...