~ Steam Mode with Heat Light Active ~
#
Components Testing
Test Points
Voltage AC
Black lead
Red Lead
+ DC
1
BCX2 (Logic Board)
J3 Connector (J3-2) GY-2
J1 Connector (J1-4) RD-1
24 VDC
2
BCX2 (Logic Board)
J4 Connector (J4-1) V-6
J1 Connector (J1-4) RD-1
24 VDC
3
BCX2 (Logic Board)
J4 Connector (J4-6) BL-2
J1 Connector (J1-4) RD-1
24 VDC
4
(T2) Bottom Transformer
Terminal #6
(WH-1)
Terminal #4
(RD-1)
24 VAC
5
( IFB ) Relay Board
J6 Connector (J6-2) W-1
J6 Connector (J6-1) RD-1
24 VAC
6
( IFB ) Relay Board
J6 Connector (J6-2) W-1
J6 Connector (J6-3) Y-6
24 VAC
7
( IFB ) Relay Board
J6 Connector (J6-2) W-1
U9 Spark Box (THS-2) Y-2
24 VAC
8
( IFB ) Relay Board
J6 Connector (J6-2) W-1
J6 Connector (J6-4) Y-3
24 VAC
9
( IFB ) Relay Board
J6 Connector (J6-2) W-1
J6 Connector (J6-5) RD-16
24 VAC
10
( IFB ) Relay Board /
(IFB) J6 Connector (J4-2) W-2
Steam Gas Valve ( MV) RD-16
Steam Gas Valve
24 VAC
~ Combi Mode with Heat Light Active ~
#
Components Testing
Test Points
Voltage AC
Black lead
Red Lead
+ DC
1
BCX2 (Logic Board)
J3 Connector (J3-1) GY-1
J1 Connector (J1-4) RD-1
24 VDC
2
BCX2 (Logic Board)
J4 Connector (J4-1) V-6
J1 Connector (J1-4) RD-1
24 VDC
3
BCX2 (Logic Board)
J4 Connector (J4-2) Y-1
J1 Connector (J1-4) RD-1
24 VDC
4
BCX2 (Logic Board)
J4 Connector (J4-6) BL-2
J1 Connector (J1-4) RD-1
(Active 25%)
24 VDC
5
(T1) Top Transformer
Terminal #6
(WH-2)
Terminal #4
(RD-2)
24 VAC
6
( IFB ) Relay Board
J4 Connector (J4-2) W-2
J4 Connector (J4-1) RD-2
24 VAC
7
( IFB ) Relay Board
J4 Connector (J4-2) W-2
J4 Connector (J4-3) OR-22
24 VAC
8
( IFB ) Relay Board
J4 Connector (J4-2) W-2
U7 Spark Box (THS-2)
24 VAC
9
( IFB ) Relay Board
J4 Connector (J4-2) W-2
J4 Connector (J4-4) OR-23
24 VAC
10
( IFB ) Relay Board
J4 Connector (J4-2) W-2
J4 Connector (J4-6) BL-1
24 VAC
11
( IFB ) Relay Board /
(IFB) J4 Connector (J4-2) W-2
Hot Air Gas Valve ( MV) BL-1
Hot Air Gas Valve
24 VAC
12
(T2)
Terminal #6
(WH-1)
Terminal #4
(RD-1)
24 VAC
Bottom Transformer
13
( IFB ) Relay Board
J6 Connector (J6-2) W-1
J6 Connector (J6-1) RD-1
24 VAC
14
( IFB ) Relay Board
J6 Connector (J6-2) W-1
J6 Connector (J6-3) Y-6
24 VAC
15
( IFB ) Relay Board
J6 Connector (J6-2) W-1
U9 Spark Box (THS-2) Y-2
24 VAC
16
( IFB ) Relay Board
J6 Connector (J6-2) W-1
J6 Connector (J6-4) Y-3
24 VAC
17
( IFB ) Relay Board
J6 Connector (J6-2) W-1
J6 Connector (J6-5) RD-16
24 VAC
18
( IFB ) Relay Board /
(IFB) J6 Connector (J4-2) W-2
Steam Gas Valve ( MV) RD-16
Steam Gas Valve
24 VAC
106
Содержание BCX-14G
Страница 65: ...EŽƚĞƐ 65 ...
Страница 68: ...1 68 ...
Страница 70: ...3 70 ...
Страница 71: ...4 71 ...
Страница 72: ...5 72 ...
Страница 73: ...6 73 ...
Страница 74: ...7 74 ...
Страница 75: ...8 I 75 ...
Страница 76: ...9 y I i w II VA w ti m dul will non 76 ...
Страница 78: ...11 If t r t n 4 th modul 100 nd th pll t r m lnln 78 ...
Страница 84: ...50 0 235 Volts AC 3Ø 2 7 Amps Forward 84 ...
Страница 85: ...50 0 235 Volts AC 3Ø 2 7 Amps Reverse 85 ...
Страница 109: ...EŽƚĞƐ 109 ...
Страница 112: ...112 ...
Страница 113: ...113 ...