Lit. No. 40688, Rev. 04
34
May 1, 2012
5. Completely drain the reservoir and replace the
drain plug.
6. With the lift ram fully retracted,
fi
ll the reservoir
through the
fi
ll hole until the
fl
uid is 1" from the top
of the reservoir.
Use
BLIZZARD
®
Rapid Action Hydraulic Fluid to
–40°F (–40°C) or other
fl
uid conforming to Military
Speci
fi
cation MIL-H-5606A, such as Mobil Aero
HFA or Shell AeroShell
®
Fluid 4.
7. Replace the breather.
8. Turn the control ON and raise and lower the blade
to reposition the draw latch.
Annual Fluid Change
1. Perform this operation with the snowplow attached
and the vehicle parked on a hard, level surface.
2. Position the blade straight across. Lower the blade
to the ground and turn the control OFF.
3. While holding the Power switch RIGHT, push
DOWN and hold the Arm/Blade Operation switch.
The arm will disengage the mount adapter and
fully retract the lift ram.
NOTE: Loosen the breather slowly to relieve any
pressure in the reservoir.
4. Remove the drain plug located in the bottom of the
hydraulic reservoir.
MAINTENANCE
AeroShell
®
is a registered trademark (
®
) of Shell Oil Company.
WARNING
To prevent accidental movement of the blade,
always turn the control OFF whenever the
snowplow is not in use. The power indicator
light will turn OFF.
CAUTION
Do not mix different kinds of hydraulic
fl
uid.
Some
fl
uids are not compatible and may
cause performance problems and product
damage.
CAUTION
Change the
fl
uid at the beginning of each
plowing season. Failure to do this could
result in condensation buildup during the
non-snowplow season.
Breather
Reservoir
Drain Plug