BLiNQ Networks Inc.
X-1200 System Installation Guide
Release 1.0
Confidential - Restricted Use and Duplication
Page
28
Issue 01 D1
6.7
Grounding and Overvoltage Protection Instructions
Ensure that you externally ground the X-1200 system modules. Two (2) grounding screws with a two-
hole lug are provided on the side of the module enclosure for this purpose. Connect the ground lug to
the main ground to safeguard against possible lightning strikes.
Further, to ensure the survivability of the indoor or outdoor connecting equipment from a lightning
strike, BLiNQ Networks recommends either installing the lightning/surge arrester that is sold separately
by BLiNQ Networks, or another suitable third-party arrester unit. This helps to provide an equipment
site that is properly grounded and protected from electrical surges.
WARNING!
The X-1200 system modules MUST be externally grounded using a
customer-supplied ground cable before power is applied. Contact
the appropriate electrical inspection authority or a qualified
electrician if you are uncertain whether suitable grounding (or
shielding from electrical surge) is available.
Lightning/surge arresters may only be connected and installed by a
qualified electrician (If used)
Always ensure that the power is OFF before performing any
grounding or overvoltage protection tasks.
All country-specific safety regulations, rules, and laws must be
observed to provide a properly grounded and overvoltage
protected equipment site.
In all X-1200 equipment installations, after the equipment is mounted, you must provide a properly
grounded and shielded environment for the installation site before connecting power or network cables.
If used, install the lightning/surge arrester in series with the Ethernet and power cables.
6.7.1
Installing the Grounding Cable
Required parts and tools:
6-gauge grounding cable
Phillips #2 screwdriver
Two (2) PH SEMS screws – ¼-20 x 3/8 in.
Crimp tool
Wire stripper
!