Confidential - Restricted Use and Duplication © Copyright 2012-2018 BLiNQ Networks Inc. All rights reserved.
BL
I
NQ
N
ETWORKS
(CCARI)
•
205
-
140
R
ENFREW
D
RIVE
,
M
ARKHAM
,
ON
L3R6B3
C
ANADA
•
1-416-214-4204
Release 2.1
Online Help Portal: support.blinqnetworks.com
FW-300i Quick Installation Guide
SYSTEM PARAMETERS
SYSTEM
Configuration
3xeNBs with frequency reuse 2 and 3
Connectivity
Default: 1 x Copper 1000BaseT; Optional: 1 x SFP
Synchronization
Integral GPS antenna (GPS, GLONASS, BeiDou),
Optional: External GPS, 1588v2
ANTENNA SPECIFICATIONS
Antenna System
3 antennas with 60deg azimuthal coverage each; 3 x 2x2
MIMO radios with spatial multiplexing/Tx & Rx diversity
Antenna Gain
17dBi
RADIO SPECIFICATIONS
3GPP LTE Feature Set
Release 10 (upgradable to Release-13
*
)
LTE-Advanced feature support: 2x2 MIMO, DL 256QAM
*
, UL
64-QAM*, 3CC Carrier Aggregation (CA)
*
Frequency Band
3.40-3.80GHz (LTE Band 42/43), 3.55-3.70GHz (LTE Band 48 -
CBRS)
Transmit Power
-10 dBm to +30 dBm per port, 1 dB resolution
Channel Bandwidth
3x10MHz or 3x20MHz (15MHz
*
)
PERFORMANCE
Throughput
L2 aggregate uplink and downlink: 115 Mbps per eNB
Supports up to 480 Mbps per eNB
*
TDD Configuration
1
Max. Throughput
(per eNB)
2-7
(default)
DL: 105Mbps UL: 10Mbps
1-6
DL: 83Mbps UL: 20Mbps
1
All TDD configurations defined in 3GPP specs supported
OPERATIONS, ADMINISTRATION AND MANAGEMENT (OAM)
Configuration
WebUI / CLI, radio, Ethernet performance monitoring
EMS Integration
SNMP v2c/v3
OAM Protocols
HTTP, HTTPS, TCP/IP, UDP, FTP, SFTP, SSH
MECHANICAL/ENVIRONMENTAL/COMPLIANCE
Dimensions (L x W x D)
13.78in x 22.4in x 8.9in (350 x 570 x 227 mm)
Weight
26.5 lbs (12 kg)
Survival Wind Speed
> 124 mph (200 km/hr)
Operational Temperature
-40 to 60 degrees Celsius (-40 to 140 degrees Fahrenheit)
Enclosure Protection
IP67
POWER
Power Consumption
(Band 46)
80 Watts (W) maximum
Power Consumption
(Band 42, 43, 48)
150 W maximum
Current Draw
(AC/DC)(Max.)
3.5 Amp
Power
48 VDC
Circuit Breaker
20A max
* Software upgrade required
FW-300i SETUP
INSTALLATION
Recommendation:
Pre-configure units in the warehouse then deploy
Record Serial number, MAC, location for each radio
Please prepare tools necessary for each item:
1/4 in. Slot Head Screw (for DC surge protector)
1/4 in. Phillips Screw (for DC surge protector)
3/8 in.-16 Hex Nuts (11/16 in. Width)
1/4 in.-20 Hex Screw (7/16 in. Head Width)
3/8 in.-16 Hex Screw (9/16 in. Head Width)
Recommended Torque Values
ITEM
TORQUE
3/8 in.-16 Hex Screws
16.3Nm or 12lb-ft
3/8 in.-16 Hex Nuts
16.3Nm or 12lb-ft
1/4 in.-20 Hex Screw (Grounding) 5Nm or 3.69lb-ft
Cabling Requirements
Power Cables (Prepare the proper extension cable)
Outdoor Rated Ethernet Cable
Grounding Cable
Make sure all cables and extensions are weatherproof
Installation (Pole Mount, Mounting Assembly and Attaching the Unit)
1
2
3
4
5
6
7
*Tilt numbers are for reference purposes.
8
Attaching Cables
Optional AC/DC Power Converter
ON POWER SUPPLY KIT
NORTH AMERICAN EQUIVALENT
ACL (Brown)
AC Line (i.e., in USA - Black)
ACN (Blue)
AC Neutral (i.e., in USA - White)
Ground (Green/Yellow)
AC Ground
Power Connector on FW-300i
Power connector:
Pin 1: Positive Polarity; Pin 2: Negative Polarity
Cables, Grounding and Lightning protection
Indicators (LED)
LED COLOUR
MEANING
Solid Red
Initial Power-up