2.5
Input cord connection (for IC3 only)
1. Choose the appropriate conduit in accordance with all applicable state, local and national
electrical codes and standards.
Figure 2-9 Conduit.
Figure 2-10 Right angle conduit
2. Clamp copper terminal to connect copper wire. The clamp point is covered by heat shrink
tube for protecting.
2-1 Refer to following wire specification. Use conductor type other than RHH, RHW and RHW-
2 with outer covering.
Model
Terminal
Conductor
Rating
Intelligent Charger-32A
L1, L2, G
8 AWG
90C copper wire
Figure 2-11 Copper terminal, heat shrink tube and copper wire.
3. Electrical wiring to the charge point.
3-1. Disassemble top cover.
1
1
Basic/Smart/Intelligent Charger-32A
Installation Manual Rev. 4.0
BlinkCharging.com • (888) 998.2546