2.4
Install the Charge Point
1. Secure the main body mounting bracket to the wall with appropriate screw.
Follow applicable accessibility requirements for the mounting position. The unit shall be stored
or located at a sufficient height.
For indoor use: The unit shall be mounted at a sufficient height from the floor between 18
inches (450 mm) and 4 feet (1.2m).
For outdoor use, it is not lower than 24 inches (600 mm) and not higher than 4 feet (1.2m).
The mounting bracket has ten screw holes. If only two screws be used to secure the mounting
bracket, the screws should pass through the middle two screw holes of the mounting bracket.
The other screw holes are reserved for the user.
Figure 2-4 Secure mounting bracket
Figure 2-5 Screw holes of mounting bracket
Screw suggestion:
A. For masonry walls, use M6 mechanical screws. (Commercially Available)
DANGER: Disconnect power at the circuit breaker before installation.
CAUTION: Before mounting determine the suitable mounting location. The unit must
be fixed to a wooden or masonry/concrete wall using hardware that is appropriate
for the surface. Do not install on drywalls, wall boards or thin plywoods. The fixing
point must be capable of supporting the weight of the unit.
7
Basic/Smart/Intelligent Charger-32A
Installation Manual Rev. 4.0
BlinkCharging.com • (888) 998.2546
©2021 Blink Charging Co. • NASDAQ: BLNK