MINIATURE TEMPERATURE SENSOR WITH 230V POWER SUPPY

SAFETY RULES

INSTALLATION - BASICS

CONNECTION DIAGRAM

temp

AC

sensor

Connection of the controller must be carried out only by 

persons with the corresponding electrician license.

"Disconnect the installation supply voltage before installing the 

controller. Remember that any mounting works should be carried 

out when the mains voltage is disconnected (switch off the mains 

fuse or disconnect the power cord from the mains socket).

The controller should be installed in a place protected against 

adverse environmental conditions, protected from third party 

access - in the flush box or inside the enclosure of the controlled 

device. Remember that metallic elements (wires, housing parts) 

have a negative influence on the range of the device, and 

consequently the comfort of use. It is recommended that the 

device be mounted in a stable and fixed position. Due to the 

operating voltage of the device it is necessary that the connectors 

of the controller be protected against accidental contacts or short 

circuits, which could cause electric shock or damage to the device.

The measurement probe is waterproof. It is not allowed to install 

the probe in a place exposed to contact with oils, liquid fuels, 

solvents and caustic substances, as well as in places exposed to 

the direct action of high temperatures.

Read the diagram and then proceed to install the controller. Pay 

particular attention to the designation of the controller connec-

tors. Start with power wires - phase L (usuallybrown) and neutral N 

(blue).

Than connect the external temperature probe, in the order of wire 

colors (from left): red and yellow and black or brown, green and 

white. If the additional probes are also installed they must be 

connected in parallel.

A digital probe was used to measure the temperature. It is not 

recommended to extend the original temperature probe cable 

excessively since the induced interference can cause the contro-

ller malfunction or even damage it.

After making sure that the device is connected in accordance with 

the diagram and that there are no metal components near the 

controllerwhich may accidentally cause short-circuit, start the 

device by turning on the power (turning on the mains fuse or 

connecting the power cord to the power outlet).

Protect the power circuit with overcurrent protection in 

B characteristic and rated current up to 6A.

DANGER! Risk of electric shock! Even with the device 

turned off, the outputs may be live. All assembly work 

should be ALWAYS performed with the disconnected 

power circuit.

Connect only in accordance with the diagram presented 

in the manual. Improper connections may be dangerous, 

it can damage the controller, and loss of the warranty.

230V AC

PROBE

temperature sensor with the
µWiFi technology

User manual

Содержание tempSensorAC

Страница 1: ...laces exposed to the direct action of high temperatures Read the diagram and then proceed to install the controller Pay particular attention to the designation of the controller connec tors Start with power wires phase L usuallybrown and neutral N blue Than connect the external temperature probe in the order of wire colors from left red and yellow and black or brown green and white If the addition...

Страница 2: ... will be controlled is 192 168 1 123 Switching on the radiator via switchBox http 192 168 1 123 s 1 Switching off the radiator via switchBox http 192 168 1 123 s 0 Opening the roller shutter via shutterBox http 192 168 1 123 s u Closing the roller shutter via shutterBox http 192 168 1 123 s d If the device was not on the found list or you want to control another device in the network select Call U...

Страница 3: ...ork check the WiFi Client status and Remote access status fields The controller is equipped with a network connection supervision system which in case of problems with connection to the WiFi or the Internet will report the problem and its possible causes If the network is working properly both fields will be set to Connected After completing the WiFi network configuration you can discon nect from ...

Страница 4: ...es field the approximate coordinates of your location should appear If the Set locations button blinks red with the word error or the Coordinates field did not change the value from Not set to numeric data a failure occurred in the location download You should then make sure that the phone tablet has a GPS module and that the location sharing support is enabled on the phone To update the software ...

Отзывы: