Transportation of Dangerous Goods a Propane Tank with an ODP Overfill Prevention Device must be used at all
times.)
IMPORTANT: Never connect the appliance to an unregulated gas supply.
If there are local codes that apply to outdoor burners, you will have to conform to them. Installation must
conform with local codes or in the absence of local codes, to the National Fuel Gas Code, ANSI Z223.1/NFPA
54 and Natural Gas Installation Code, CSA B149.1. All Natural Gas installations must conform to local codes or
in the absence of local codes the national fuel gas code, ANSIZ2223.1a-
‐
1998.
If there are local codes that apply to outdoor burners, you will have to conform to them. Installation must conform
with local codes or, in the absence of local codes, with Propane Installation Code, CSA B149.1, or Propane
Storage and Handling Code, B149.2 as applicable.
Installation in Canada must be in accordance with the standard CAN/CGA- B149.2.
A licensed contractor or local gas company representative must perform all gas connections.
Ensure that the service supplying the appliance is fitted with a shut off valve conveniently positioned near the
appliance and giving ease of access.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system.