BLAUBERG Sileo V2 Скачать руководство пользователя страница 1

EN

 Sileo V2 

OPERATION MANUAL 

Содержание Sileo V2

Страница 1: ...EN Sileo V2 OPERATION MANUAL ...

Страница 2: ... mains must comply with the acting local electrical norms and standards The fixed electrical wiring must be equipped with an automatic circuit breaker The fan must be connected to power mains through an automatic circuit breaker QF integrated into the fixed wiring system with the gap between the breaker contacts on all poles not less than 3 mm Check the fan for any visible damages of the impeller ...

Страница 3: ... combustion products into the room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials 3 WARNING Follow the user s manual requiremen...

Страница 4: ...on the fan and do not put objects on it The timer circuit is live Disconnect the fan from power supply prior to any adjustment operations The fan delivery set includes a specially designed plastic screwdriver for adjustment of the fan parameters Use the plastic screwdriver to change the turn off delay time 4 WARNING Follow the user s manual requirements to ensure durable and trouble free operation...

Страница 5: ...struction regarding a safe use of the product and understand the risks involved Do not allow children play with the product Fan cleaning and maintenance must only be performed by children under adult supervision The product must be collected separately at the end of service life Do not dispose of as unsorted municipal waste 5 WARNING Follow the user s manual requirements to ensure durable and trou...

Страница 6: ...in Fig 18 OPERATION GUIDELINES The fan is rated for connection to AC single phase 220 240 V 50 Hz The fan is rated for operation at the ambient air temperature from 1 C up to 45 C Ingress protection rating against access to hazardous parts and water ingress is IP 45 The fan requires no grounding MOUNTING The fan is designed for vertical or horizontal installation and connection to a ventilation sh...

Страница 7: ...nce in 1 second the turn off delay timer is activated WARNING If the switch is OFF or the indoor humidity falls below the set point within 60 seconds after activation of the switch or the humidity sensor the fan continues operation with the low speed MAINTENANCE The fan maintenance periodicity is at least once per 6 months Uplift the latches carefully and open the front cover with a flat screwdriv...

Страница 8: ... to elimination of faults in the fan operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the fan components or a specific part of such fan component The warranty repair does not include Routine technical maintenance Fan installation dismantling Fan setup To benefit from warranty repair the user mu...

Страница 9: ...er s violation of the fan transportation regulations User s violation of the fan storage regulations Wrongful actions against the fan committed by third parties Fan breakdown due to circumstances of insuperable force fire flood earthquake war hostilities of any kind blockades Missing seals if provided by the user s manual Failure to submit the user s manual with the fan purchase date stamp Missing...

Страница 10: ...10 2 1 3 Sileo V2 125 124 D mm 182 B mm 158 H mm 91 L mm 27 L1 mm Sileo V2 100 99 158 136 81 26 D L L1 H B ...

Страница 11: ...11 6 10 7 4 11 8 5 12 9 6 QF L N ...

Страница 12: ...LT L N N L QF N L QF Sileo V2 100 125 low speed Fan runs with low speed Fan does not run LT L N LT L N Switch S is OFF Switch S is ON Sileo V2 100 125 S low speed Sileo V2 100 125 high speed Sileo V2 100 125 S high speed High speed Fan does not run Switch S is ON Switch S is OFF Fan runs with high speed ...

Страница 13: ... N L QF S speed S N L QF S speed LT L N N L QF S S N L QF speed Sileo V2 100 125 low and high speed Fan does not run Fan runs with high speed Sspeed in position L or LT LT L Fan runs with ow speed Switch S is ON LT L N LT L N Switch S is OFF Sileo V2 100 125 S low and high speed ...

Страница 14: ...S is ON Switch S is OFF Activation of turn off delay timer 2 30 minutes Off Activation of the interval timer 6 12 24 hours Fan does not run 6 12 24 hours Fan runs with low speed Switch S is ON Activation of turn on delay timer 60 seconds yes no Switch S is OFF during countdown of turn on delay timer Fan runs with high speed Switch S is OFF Activation of turn off delay timer 2 30 minutes Activation...

Страница 15: ...2 30 minutes Fan runs with low speed Switch S is OFF Switch S is OFF Sileo V2 100 125 H LT L N N L QF S LT L N N L QF S Switch S is OFF during countdown of turn on delay timer no no no yes yes yes Humidity is above set point Humidity is above set point Activation of turn on delay timer 60 seconds Fan runs with high speed Fan runs with high speed Humidity is below set point ...

Страница 16: ...kwise to increase and counter clockwise to decrease the turn off delay time respectively adjustable from 2 up to 30 minutes To adjust the humidity set point turn the control knob H clockwise to increase and counter clockwise to decrease the humidity sensor set point adjustable from 60 up to 90 Warning The timer circuit is live Disconnect the fan from power supply prior to any adjustment operations...

Страница 17: ...17 24 25 22 23 20 21 QF L N Latches ...

Страница 18: ...18 notes ...

Страница 19: ...CCEPTANCE CERTIFICATE WARRANTY CARD The fan is recognized as serviceable Stamp of the acceptance inspector Manufacturing date Sold by name of the vendor stamp of the shop Date of sale 100 Sileo V2 S T 125 H ...

Страница 20: ...Sileo V2 Sileo V2 v1 1 EN ...