Supply voltage, 50 (60) Hz [V]

110-230

Maximum current [A] 

0.012

Cable type 

2х0.35 mm

2

Temperature range [°C] 

from +10 up to +45

Humidity range [%] 

10-80 (without condensation)

Casing material 

Plastic

Sensor surface material 

Glass

SEC class 

IP30

Weight [g]

190

DIMENSIONS

Control panel

 86 mm 

R 2 mm 

42.5 mm 

13.5 mm 

68 mm 

 82 mm 

 60 mm 

Wi-Fi data

Standard 

IEEE 802.11 b/g/n

Frequency band [GHz 2.4]

2.4

Transmission power [mW] (dBm)

100 (+20)

Network 

DHCP

WLAN safety 

WPA, WPA2

Mounting box

 

94 mm 

34 mm 

3 mm

TECHNICAL DATA

CUT OFF POWER SUPPLY BEFORE ANY OPERATIONS ARE PERFORMED

THE CONTROL PANEL MUST BE INSTALLED  BY A QUALIFIED EXPERT ONLY, PROPERLY 

TRAINED AND HAVING THE REQUIRED TOOLS AND MATERIALS

MOUNTING, CONNECTION AND SETUP

CHOOSING LOCATION FOR CONTROL PANEL INSTALLATION

Examples of wireless alternatives and system operation scenarios

Example 1

: direct control panel connection to master ventilator without using a router. 

The control panel must be installed within the range of the Wi-Fi access point built into the master ventilator.

Master ventilator 

(Wi-Fi access point)

 

Mobile device Mobile device

Control panel 

(Wi-Fi client)

Control panel 

(Wi-Fi client)

Set the ventilator to Wi-Fi access point master mode (see 
the ventilator user’s manual).
•  Install the control panel within the range of the Wi-Fi 

access point built into the ventilator.

•  Pair the control panel with the ventilator (see below).
Note: the limitations specific to the number of devices 
that can be connected to the ventilator in the Wi-Fi 
access point mode are detailed in the ventilator user’s 
manual.

Содержание SE Vento Expert W

Страница 1: ...Sensor control panel with integrated Wi Fi USER S MANUAL EN SE VENTO Expert W ...

Страница 2: ...hnical norms and standards must be observed when installing and operating the unit Disconnect the unit from the power supply prior to any connection servicing maintenance and repair operations Only qualified electricians with a work permit for electrical units up to 1000V are allowed for installation and maintenance The present user s manual should be carefully read before beginning works Check th...

Страница 3: ...use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance The connection to the supply mains must be made through a means of d...

Страница 4: ...toren de PURPOSE DELIVERY SET NAME NUMBER Control panel 1 pc Mounting box 1 pc User s manual 1 pc Packing 1 pc The sensor control panel is designed to control the TwinFresh Expert from version V 2 and TwinFresh Style Wi Fi series ventilators ...

Страница 5: ...EQUIRED TOOLS AND MATERIALS MOUNTING CONNECTION AND SETUP CHOOSING LOCATION FOR CONTROL PANEL INSTALLATION Examples of wireless alternatives and system operation scenarios Example 1 direct control panel connection to master ventilator without using a router The control panel must be installed within the range of the Wi Fi access point built into the master ventilator Master ventilator Wi Fi access...

Страница 6: ...uter to one of the Wi Fi access points see ventilator user s manual Pair the ventilator with the first group of the panels Connect the ventilator to the other Wi Fi access point see ventilator user s manual Pair the ventilator with the other group of the panels ATTENTION IRRESPECTIVE OF THE SELECTED CONNECTION PATTERN THE PANEL MUST BE WITHIN THE RANGE OF THE WI FI ACCESS POINT BUILT INTO THE VENT...

Страница 7: ...lf tapping screws purchased separately 2 Connect the control panel according to the electrical connections diagram N L 110 230 V 50 60 Hz 3 Unfasten gently the latches on the lower part of the glass control panel using a screwdriver Take off the control panel Then disconnect the sensor board from the connector on the casing 4 Fasten the control panel casing to the mounting box with screws The scre...

Страница 8: ...et to 4 hours by default or the Night mode speed 1 enabled by the timer set to 8 hours by default To activate the Party mode press the button and then immediately press the button To activate the Night mode press the button and then immediately press the button The filter contamination indicator activates automatically after 90 hours of unit operation Respond to the alert by replacing or cleaning ...

Страница 9: ...ble hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage The unit must be transported only in the working position Avoid sharp blows scratc...

Страница 10: ...ion dismantling unit setup To benefit from warranty repair the user must provide the unit the user s manual with the purchase date stamp and the payment paperwork certifying the purchase The unit model must comply with the one stated in the user s manual Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with ...

Страница 11: ...STALLATION CERTIFICATE The SE VENTO Expert W unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction electrical and technical codes and stan...

Страница 12: ...www blaubergventilatoren de B133 2EN 03 ...

Отзывы: