Страница 1: ...Impulse centrifugal fan USER S MANUAL EN Centro Jet...

Страница 2: ...Company reserves the right to modify the technical characteristics design or configuration of its products at any time in order to incorporate the latest technological developments No part of this pub...

Страница 3: ...g the unit control the user s manual must be turned over to the receiving operator UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS Disconnect the unit from power mains prior to any installation ope...

Страница 4: ...the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or em...

Страница 5: ...n of chemicals sticky substances fibrous materials coarse dust soot and oil particles or environments favourable for the formation of hazardous substances toxic substances dust pathogenic germs THE UN...

Страница 6: ...F H L K Centro Jet 50N 290 1355 935 1005 1065 90 180 350 96 Centro Jet 85N 330 1605 1105 1175 1235 110 230 390 136 Centro Jet 100N 330 1605 1105 1175 1235 110 230 390 138 TECHNICAL DATA Centro Jet X...

Страница 7: ...5 55 C 55 C Centro Jet 85N 4 200 2 200 C 2 hours F200 Centro Jet 85N 4 300 2 300 C 2 hours F300 Centro Jet 85N 4 400 2 400 C 2 hours F400 85N double speed Centro Jet 85N 4 6 3 400 50 9750 5950 2 2 0 7...

Страница 8: ...motor or a double speed 4 6 or 4 8 pole asynchronous motor Steel impeller with backward curved blades Before installing the unit carry out the following checks Make sure that the fan impeller rotates...

Страница 9: ...tion method i e overhead in pipes or inside the walls Connection of the fan for smoke extraction must be performed via a cable with a respective fire resistance class Quality and mounting of the fire...

Страница 10: ...Centro Jet 50N 4 Centro Jet 85N 4 Centro Jet 100N 4 X1 L3 L1 L2 U1 W1 V1 U2 W2 V2 PE L2 L3 L1 1 2 3 4 5 6 400 V 50 Hz 400 V 60 Hz Double speed Centro Jet 50N 4 6 Centro Jet 85N 4 6 Centro Jet 100N 4...

Страница 11: ...SS starting A soft starter gradually increases the voltage supplied to the motor from the initial to the rated value This starting system can be used to meet the following goals limit the motor curren...

Страница 12: ...circuit breakers contactors and motor starters is not designed to withstand prolonged overloads normally causing the fan to shut down automatically DOL starting that continues for a long period of ti...

Страница 13: ...hub for proper tightness and tighten it up if necessary Check the bolt connecting the motor shaft to the hub for proper tightness and tighten it up if necessary Technical maintenance must be carried...

Страница 14: ...ons The installed automatic circuit breaker is of poor quality or its actual performance falls short of the rated values stated by the manufacturer Re select the automatic circuit breaker by choosing...

Страница 15: ...objects or debris Clean the impeller from foreign objects or debris Increased noise vibration in the fan Loose screw connections Check the screw connections for proper tightness No vibration mounts o...

Страница 16: ...andling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechani...

Страница 17: ...nation of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the unit componen...

Страница 18: ...Centro Jet 18 www blaubergventilatoren de...

Страница 19: ...___ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date Signat...

Страница 20: ...www blaubergventilatoren de B117EN 03...