6.5
Venting hydraulic pump E03996_1
1.
Push the treddle (#1) down into drive-mode
2.
Fill the reservoir (#2) to oil level cold mark with E00481 Hydraulic oil.
3.
Keep the “dump valve shaft” (#3) pushed in.
The easiest way is to use a piece of wood approximately 1 meter long.
4.
Drive the machine forwards and backwards (#4) while keeping “dump valve shaft” (#3) pushed in.
Note:
It could take up to 15 minutes before all air-bubbles are out of the system.
5.
Fill reservoir (#2) to proper fluid level.