BDC-3140P
07/2008
9
C324
I
GB
F
D
E
Vacuum cleaner disposal
Dispose of the vacuum cleaner in compliance with the laws in
force.
Wiring diagrams
Figure 14 - 15
Item
Part
Code of the model
230V/60Hz 400V/50Hz 440V/60Hz
Q1
Main switch
8 39989
Q2
Circuit breaker
8 39535
8 39726
8 39916
8 39726
8 39014
8 39726
KM1
Contactor
8 39102
8 39838
8 39281
8 391105
TS2
Cyclic timer
8 391107
Recommended spare parts
Code
Description
Quantity
S08BL33008 Filter cartridge
3
8 17026
Filter gasket
3
8 17753
HEPA filter cartridge
1
HEPA filter replacement (optional)
Figure 11
1
Air inlet hose
2
Filter cover
3
Release lever
4
HEPA filter
Before proceeding with these operations, turn off the vacuum
cleaner and remove the plug from the power socket.
■ Remove the air inlet hose (
1
).
■ Use the levers (
3
) to remove the cover (
2
).
■ Remove the filter (
4
).
■ Assemble the new filter and install all the components in
the reverse order of removal.
■ Dispose of the old filter according to the laws in force.
Motor cooling fan inspection and cleaning
Periodically clean the motor cooling fan to prevent the motor
from overheating, especially if the vacuum cleaner is used in
a dusty place.
Tightness inspection
Figure 12
1
Suction connecting hose
2
Hose
■ Hoses check
Make sure that the suction connecting hose (
1
) is in a
good condition and correctly fixed.
If the hose is damaged, broken or badly connected to the
unions, it must be replaced.
When sticky materials are treated, check for possible clogging
along the hose (
2
), in the inlet and on the baffle plate inside the
filtering chamber.
Scrape the inlet from the outside and remove the
deposited waste as indicated in the figure.
Figure 13
1
Gasket
2
Screws
3
Filtering chamber
■ Filtering chamber tightness check
If the gasket (
1
) between the container and the filtering
chamber (
3
) fails to guarantee tightness:
▪ Loosen the four screws (
2
) that lock the filtering
chamber (
3
) against the vacuum cleaner structure.
▪ Allow the filtering chamber (
3
) to lower down and
tighten the screws once it has reached the tightness
position (
2
).
The gasket (
1
) must be replaced if it is torn, cut, etc...
Содержание BDC 3140 P
Страница 3: ......
Страница 54: ...BDC 3140P 07 2008 1 C324 1 2 3 1 9 10 6 12 5 8 7 16 15 3 11 2 13 14 4 VOLT B C A B A C...
Страница 55: ...C324 2 07 2008 BDC 3140P 1 5 4 6 1 1 2 4 5 6 7 3 8 9 10 11...
Страница 56: ...BDC 3140P 07 2008 3 C324 7 9 10 1 2 8 2 3 1 T3 T2 T1 1 2 4 3 7 6 9 8 5 10...
Страница 57: ...C324 4 07 2008 BDC 3140P 11 12 13 2 1 3 4 2 1 2 1 2 3...
Страница 58: ...BDC 3140P 07 2008 5 C324 14 Q1 Q2 KM1 Q2 Q2...
Страница 59: ...C324 6 07 2008 BDC 3140P 15 1 2 3 TS2 KM1 KM1...
Страница 60: ......