background image

BLACKMER LIQUEFIED GAS PUMPS 

960417

 

INSTRUCTIONS NO. 501-C00 

FOR LP-GAS AND NH

SERVICE TRUCK AND BASE MOUNTED 

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS

 

MODELS: LGLD2E, LGL2E, LGLD3F, LGL3F 

and discontinued LGLD3E, LGL3E 

Section 

Effective 

Replaces 

501 
Apr 2020 
Jan 2019 

 

 
 

 

 
TABLE OF CONTENTS 

Page

 

SAFETY DATA

 ..................................................................... 1

 

PUMP DATA

 

 

Pump Identification ..................................................... 2 

 

Technical Data ........................................................... 2 

 

Initial Pump Start Up Information ............................... 2 

GENERAL INSTALLATION AND OPERATION

  

 

Welded Connections .................................................. 3 

 

Pre-Installation Cleaning ............................................ 3 

 

Location and Piping .................................................... 3 

 

Pump Relief Valve and Bypass Valve ........................ 4 

 

Check Valves ............................................................. 4 

 

Pump Rotation ........................................................... 4 

MOTOR DRIVEN PUMPS 

 

 

Pump Mounting .......................................................... 4 

 

Coupling Alignment .................................................... 5 

 

V-Belt Drive ................................................................ 5 

 

V-Belt Disassembly .................................................... 5 

 

Pre-Start Up Check List ............................................. 6 

 

Start Up Procedures ................................................... 6 

TRUCK MOUNTED PUMPS

 

 

Truck Mounting .......................................................... 6 

 

Pump Drive ................................................................ 6 

 

Hydraulic Drive ........................................................... 7 

 

Pre-Start Up Check List ............................................. 7 

 

Start Up Procedures ................................................... 7 

 

Pump Speed .............................................................. 8 

MAINTENANCE 

 

Strainers ..................................................................... 8 

 

Lubrication ................................................................. 8 

  Vane Replacement ..................................................... 9 
  Pump Disassembly .................................................... 9 
  Pump Assembly ....................................................... 10 

TROUBLE SHOOTING

 ...................................................... 12 

 
NOTE

:  Numbers  in  parentheses  following  individual  parts 

indicate reference numbers on Blackmer Parts List 501-C01 
 
Blackmer pump manuals and parts lists may be obtained from 
Blackmer's  website  (www.blackmer.com)  or  by  contacting 
Blackmer Customer Service. 

SAFETY DATA 

 

This is a SAFETY ALERT SYMBOL. 

When you see this symbol on the product, or in the manual, 
look for one of the following signal words and be alert to the 

potential for personal injury, death or major property 

damage 

 

Warns of hazards that WILL cause serious personal injury, 

death or major property damage. 

 

Warns of hazards that CAN cause serious personal injury, 

death or major property damage. 

 

Warns of hazards that CAN cause personal injury 

or property damage. 

NOTICE: 

Indicates special instructions which are very 

important and must be followed. 

 

 

 

NOTICE: 

Blackmer liquefied gas pumps MUST only be installed 
in  systems  which  have  been  designed  by  qualified 
engineering personnel. The system MUST conform to 
all applicable local and national regulations and safety 
standards. 

This manual is intended to assist in the installation and 
operation  of  the  Blackmer  liquefied  gas  pumps,  and 
MUST be kept with the pump. 

Blackmer  liquefied  gas  pump  service  shall  be 
performed by qualified technicians ONLY. Service shall 
conform to all applicable local and national regulations 
and safety standards. 

Thoroughly  review  this  manual,  all  Instructions  and 
hazard warnings, BEFORE performing any work on the 
Blackmer liquefied gas pumps. 

Maintain ALL system and Blackmer liquefied gas pump 
operation and hazard warning decals. 

 

 

Содержание LGL2E

Страница 1: ...er com or by contacting Blackmer Customer Service SAFETY DATA This is a SAFETY ALERT SYMBOL When you see this symbol on the product or in the manual look for one of the following signal words and be a...

Страница 2: ...d decontaminated inside and out prior to performing service or maintenance Hazardous or toxic fluids can cause serious injury PUMP DATA PUMP IDENTIFICATION A pump Identification tag containing the pum...

Страница 3: ...intake port on the pump Slope the pipe downward to the pump and do not install any upward loops Minimize the number of intake line fittings and eliminate restrictions such as sharp bends globe valves...

Страница 4: ...added starting torque can damage the pump and related equipment PUMP ROTATION NOTICE Confirm correct pump rotation by checking the pump rotation arrows respective to pump driver rotation Blackmer LGL...

Страница 5: ...152C G 5 Measure the span length as shown in Figure 6 6 Adjust the motor base 183 and apply a specified force see Table 1 against the belt at the center of the span so that the belt is deflected 1 64...

Страница 6: ...osed valve can cause system failure personal injury and property damage Hazardous pressure can cause personal injury or property damage LGLD TRUCK MOUNTED PUMPS Failure to set the vehicle emergency br...

Страница 7: ...alve is a Lever Operated Pull the control knob all the way out Manually check the lever under the truck to see that it is in the completely OPEN position b Discharge Pressure Operated Keep the dischar...

Страница 8: ...essure can cause personal injury or property damage Hazardous or toxic fluids can cause serious injury NOTICE Maintenance shall be performed by qualified technicians only following the appropriate pro...

Страница 9: ...and 24B a Bend up the engaged lockwasher tang and rotate the locknut 24A counterclockwise to remove it from the shaft b Slide the lockwasher 24B off the shaft Inspect the lockwasher for damage and re...

Страница 10: ...Insert the new vanes into the rotor slots with the rounded edges outward and the vane relief grooves facing TOWARDS the direction of rotation See Figure 8 c After the bottom vanes and push rods are in...

Страница 11: ...ed by hand g To check adjustment grasp the nut and washer with fingers and rotate back and forth If this cannot be done one or both locknuts are too tight and should be alternately loosened one stop a...

Страница 12: ...kes 4 Pump driver driveline drive shaft misalignment Excessively worn vanes or vane slots Mechanical Seal Leakage 1 O rings not compatible with the liquids pumped 2 O rings nicked cut or twisted 3 Sha...

Отзывы: