background image

www.BlacklineSafety.com

Содержание G7 BRIDGE

Страница 1: ...www BlacklineSafety com...

Страница 2: ...talented team of designers and engineers create and manufacture everything in house In house Safety Monitoring Center and Customer Care We offer services in over 100 countries Currently monitor over...

Страница 3: ...WHAT IS G7 Work everywhere wearable personal safety monitor with gas detection 18 hours battery 2 way texting Deliver instant situational awareness Manage fastest response Intrinsically Safe Standard...

Страница 4: ...able satellite cellular base station Works with G7x to monitor your safety even when out of cell range Delivers mass notifications Is capable of connecting to up to five G7x devices with a range of 2k...

Страница 5: ...PLANS Self monitored Your team monitors your Blackline Live account Blackline Monitored Blackline Safety s in house monitoring personnel monitor your team 24 7 365 days a year 99 5 of alerts responded...

Страница 6: ...HARDWARE DETAILS G7x...

Страница 7: ...ETAILS G7 BRIDGE Power button Charging light Weatherproof enclosure Base Charging port Sealing plug removable Product label OK button Up button LCD screen Down button SureSafe OK Alarm light Side ligh...

Страница 8: ...MOUNTING Top of vehicle Dash On site ALWAYS MAKE SURE G7 BRIDGE HAS A CLEAR VIEW OF THE SKY ESPECIALLY WHEN OUTSIDE CELL COVERAGE...

Страница 9: ...onnected to the Blackline Safety Network A blinking SureSafe Light means your device is trying to connect Don t panic It s OK to have a blinking light for small amounts of time SURESAFE LIGHT Press th...

Страница 10: ...ill let you know it s time to bump or calibrate upon start up What do I do Press and hold the up and down arrows to silence this reminder Then bump or calibrate using one of the methods on the next sl...

Страница 11: ...e lid 3 Select bump test calibration from the menu 4 Let G7 Dock do its thing You can bump and calibrate in one of two ways Manually 1 Press OK to access the menu 2 Use the up and down arrows to navig...

Страница 12: ...WEARING Belt Chest DO NOT LEAVE G7 UNATTENDED WHEN POWERED ON THIS CAN LEAD TO FALSE RED ALERTS...

Страница 13: ...YELLOW PENDING ALARM What do I do Are you OK If yes press the latch to return the device to normal function Fall detection Check in timer No motion YELLOW PENDING ALARM...

Страница 14: ...ou re OK What do I do Press and hold the up and down arrows to mute the device Remember this doesn t cancel the alert RED ALERT YELLOW PENDING ALARM If you don t confirm you re OK the Yellow Pending A...

Страница 15: ...LERT If you need to request help right away you can trigger a SOS Alert What do I do Pull the latch How do I silence the alarm Press and hold the up and down arrows Remember this does not cancel the a...

Страница 16: ...s certain gas alerts will automatically generate a red alert and notify monitoring personnel What do I do Evacuate the area When it is safe to do so press and hold the up and down arrows to mute G7 s...

Страница 17: ...p The LiveResponse light will flash blue when monitoring personnel respond to your Alert using your company s alert response protocol When it shines on your device it means someone will be contacting...

Страница 18: ...down arrows to silence the device New message YELLOW WARNING ALARM Low battery Bump Test Network Connection Interruption Calibration Low warning alarm for gas Sensor error Under limit Remember Yellow...

Страница 19: ...ENDING Sending a message 1 Press OK 2 Select send message 3 Scroll to the message you want to send press OK Receiving a message 1 Read your message 2 Press and hold the up and down arrows for 3 second...

Страница 20: ...upplied air or self contained breathing apparatus Leak check For checking an area for leaks with or without pump High risk For general high risk situations like evacuations Pump run Runs the pump cont...

Страница 21: ...do I do Press the up arrow to extend the mode Press the down arrow to exit the mode If you do not confirm that you would like to extend your mode within 30 seconds G7 will return to normal mode and i...

Страница 22: ...ch as pre entry or leak check 3 Perform a block test following the steps on G7 s screen 4 Pump will start automatically NOTE if the block test fails the device will not enter the mode and pump won t s...

Страница 23: ...ock test G7 will enter the mode and pump will turn on If you fail the block test G7 will return to normal mode MANUAL BLOCK TEST This is the block test that you can perform anytime a pump is running T...

Страница 24: ...ch as If the pump is on off Hose length set from the pump options menu Flow rate in real time maintained by G7 Sample timer if enabled from pump options PUMP OPTIONS MENU The pump options menu is avai...

Страница 25: ...ing your device has been fully powered down and your safety is no longer being monitored Press and hold G7x s power button for 3 seconds to turn the device off Press and hold G7 Bridge s power button...

Страница 26: ...CHARGING G7x has an 18 hour battery life Remember to charge after every shift What do I do Put the clip into the base of the G7 then plug in the micro USB...

Страница 27: ...CHARGING G7 Bridge has a 50 hour battery life Remember to charge after every shift What do I do Put the clip into the side of G7 Bridge then plug in the micro USB...

Страница 28: ...QUESTIONS...

Страница 29: ...technical support please contact our Customer Care team support BlacklineSafety com North America 24 hours Toll Free 1 877 869 7212 support blacklinesafety com International 24 hours 1 403 452 0327 su...

Отзывы: