Black Max BM903511 Скачать руководство пользователя страница 1

15-30 S

99100004

5-20-14 (REV:01)

Install the feet 

(see page 11).

WARNING:

This Quick Reference Guide is not a substitute for reading the operator’s manual. To reduce the risk of injury or death, user must read and understand operator’s manual before using this product. All page references refer to 
the operator’s manual.

FIRST TIME ASSEMBLY

1

BM903511 QUICK REFERENCE GUIDE

STARTING THE UNIT

USING THE GENERATOR

5

Add entire bottle of lubricant provided to the gen-

erator 

(see page 13).

Add fuel 

(see page 14).

1

2

Turn the fuel valve to ON 

(see page 14).

Turn the fuel valve to OFF before adding lubri-

cant.

Set unit on flat surface so engine is level.

Remove dipstick, wipe clean, put back in hole 

(but don’t screw in) and check lubricant level.

This is a 4-cycle engine. Do not mix fuel and 

lubricant   together.

Mix fuel stabilizer with gasoline according to 

manufacturer’s directions prior to filling the 

tank.

STOPPING THE UNIT

Press and hold the STOP switch 

(see page 14.)

1

Connect devices to be powered by generator by following the steps below 

(see pages 8-9).

Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you

will power at the same time. See page 9 for how to calculate total amount of power needed.

Start the generator with nothing connected.

Plug in and turn on the first load, preferably the largest load you have.

Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).

Plug in and turn on the next load.

Again, permit the generator to stabilize.

Repeat previous two steps for each additional load.

IMPORTANT: Never add more loads than the generator capacity. Take special care to consider surge loads in 

generator capacity. 

(See pages 8-9.)

1

TROUBLESHOOTING

STORING THE UNIT

When preparing to store the generator, allow the unit to cool completely, then follow the guidelines listed on 

page 18.

1

WARNING:

 

Do not connect to a building’s electrical 

system unless the generator and transfer 

switch have been properly installed and 

the electrical output has been verified by 

a qualified electrician. The connection 

must isolate the generator power from 

utility power and must comply with all 

applicable laws and electrical codes.

IMPORTANT!

Only use OUTSIDE and

far away from windows,

doors, and vents.

NEVER use inside a home

or garage, EVEN IF doors

and windows are open.

Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a 

poison you cannot see or smell.

PROBLEM

POSSIBLE CAUSE

SOLUTION

Engine will not start.

No fuel.
Stale gasoline or water in gasoline.
Lubricant level is low.

Fuel valve is OFF.
Spark plug faulty, fouled, or improperly gapped.

Choke is in RUN position.
Engine stored without treating or draining gaso-

line, or refueled with bad gasoline.
Dirty fuel filter.

Fill fuel tank.
Drain entire system and refill with fresh fuel.
Engine is quipped with Low Oil Shutoff. if engine 

lubricant level is low, it must be filled before unit 

will start.Check engine lubrincant level and fill, 

if   necessary.
Turn fuel valve ON.
Replace spark plug. 

Move choke to START position.
Drain fuel and carburetor. Refuel with fresh 

gasoline.
Replace fuel filter or contact authorized service 

center

Engine hard to start.

Water in gasoline.
Weak spark at spark plug.

Drain entire system and refill with fresh fuel.
Replace spark plug or contact authorized ser-

vicee center.

Engine lacks power.

Air filter element clogged.

Engine stored without treating or draining 

gasoline, or refueled with bad gasoline.

Check air filter element. Clean or  replace as 

needed.
Drain fuel and carburetor. Refuel with fresh 

gasoline. If problem continues, contact your 

nearest authorized service center.

AC receptacle does not work.

Circuit breaker is OFF.
Item plugged in is defective.

Turn ON the AC circuit breaker.
Try a different item.

Generator makes a “spark 

knock” or “pinging” noise.

An occasional light “knocking” or “pinging” under 

heavy load is not a cause for concern. However, 

if the knocking or pinging occurs under normal 

load at a steady engine speed, the problem may 

be with the brand of gasoline being used.

Switch to a different brand of gasoline, making 

sure that the octane rating is 86 or higher. If 

problem continues, contact your nearest autho-

rized service center.

If problem persists after trying the above solutions, contact your nearest authorized service center for assistance.
The following symptoms may indicate problems that will affect the emissions level of the unit: 

Hard starting or stalling after starting

Rough idle

Misfiring or backfiring under load

Afterburning (backfiring)

Black exhaust smoke or high fuel consumption

If you encounter any of these symptoms, have the unit inspected and repaired by the nearest authorized service  center.

If you need more assistance, visit our website at 

 www.blackmaxtools.com or call us at 1-800-726-5760.

R

Allow engine to run for 15-30 seconds, then push 

choke in to RUN position 

(see page 14).

5

Pull the recoil starter to start

(see page 14).

4

3

Pull choke out to START position 

(see page 14).

CHOKE 

IN RUN 

POSITION

STOP SWITCH

NOTICE:

 

Do not use E15 or 

E85 fuel (or fuel 

containing greater than 10% ethanol) in 

this product. It is a violation of federal 

law and will damage the unit and void 

your warranty.

CHOKE IN 

START POSITION

CHOKE

OFF

ON

Install the handle 

(see page 12).

3

Install the wheels 

(see page 12).

2

Securing the handle 

(see page 12).

4

TOOLS NEEDED

Socket Wrench

Adjustable Wrench