47

MODULAR SMART SWITCH 

<PM CONNECT port SOFTWARE:DISABLE>

9.2.6  R

EMOVING

L

INE

F

EEDS AT

E

ND OF

S

OFTWARE

C

OMMANDS

When programming applications such as DBASE to automatically send data to
a specific printer, you might want to remove linefeed and carriage-return
characters that are automatically inserted by the application at the end of the
software command.  To do this, add an “ignore” instruction to the software
command as follows:

<PM CONNECT port IGNORE>

When the Modular Smart Switch receives such an instruction, it will delete

the line feed (CR or LF or both) following the software command.

9.3  Clear Command

The clear command allows a computer to delete any data that has been sent
into the Modular Smart Switch that has not yet been printed.  As with all
software commands, this only affects the data from the computer that sends
the command.  The format is:

<PM CLEAR>

9.4  End-of-File Command

Sending the end-of-file command terminates the present input file.  It is used
when the timeout option has been set “off,” since it will allow other
computers access to the printer.  If multiple copies are required, the end-of-
file command indicates the end of the document.  A new command will also
automatically terminate the present input file.  The format used for the end-
of-file command is as follows:

<PM EOF>

9.5  Creating Batch Files to Send Commands (IBM Compatible PCs)

On IBM compatible PCs, batch files are a convenient way to send commonly
used software commands.  To create batch files, proceed as follows:

At the DOS prompt, type:

COPY CON: {name}.TXT [enter]
<PM CONNECT {channel number} >[function key 6]

46

MODULAR SMART SWITCH

9.2.4  V

ARYING THE

T

IMEOUT

P

ERIOD

The timeout sets the length of time that the output port remains dedicated
to the input port once the incoming data has ceased.  It can be set to any
number of seconds between 1 and 255, or it can be switched off.  With the
timeout off, the output channel remains constantly dedicated to the input
channel until an end of file command (see 

Section 9.4

), or a new connect

command is sent.  The timeout remains as set until it is changed again,
or the Modular Smart Switch is powered off.

To change the timeout, a connect command is sent with the timeout

option specified after the required destination port, as follows:

<PM CONNECT port TIMEOUT:value>

The timeout value is either a number 1 to 255 or the word OFF.

For example, if a computer requires uninterrupted use of the printer
connected to port 1 until further notice, the command below would be sent:

<PM CONNECT 1 TIMEOUT:OFF>

9.2.5  D

ISABLING

S

OFTWARE

C

OMMANDS

When communicating with another computer using a file-transfer protocol
such as that used by Laplink or Xmodem, you can temporarily turn off the
command interpretation while files are being transferred.  This is because
some of these protocols expect a checksum character to be sent back as an
acknowledgement after a block of data has been sent.  If this character
happens to be the start character (<) of a software command, a delay can
occur that may cause the transfer software to time out.  To make sure that
this does not happen, you can set the Modular Smart Switch to ignore
software commands during file transfer.  To do this, use the “software sleep”
command.  Once a “software sleep” command has been sent, the Modular
Smart Switch will not interpret new commands until the data transfer has
timed out.  This will occur after no data has been sent for the timeout period.
To set “software sleep” mode, send the following command:

<PM CONNECT port SOFTWARE:SLEEP>

To restore normal software command interpretation, send the following

command when the data has timed out.

<PM CONNECT port SOFTWARE:ENABLE>

Software command interpretation can also be permanently disabled using

the following command.  Once this command has been issued, no software
commands will be interpreted until the Modular Smart Switch has been reset
(by switching the power off).

Содержание SW925A

Страница 1: ...hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com APRIL 20...

Страница 2: ...s operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever mea...

Страница 3: ...ser le das antes de que el aparato el ctrico sea operado 2 Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura 3 Todas las advertencias en el aparato el ctrico y e...

Страница 4: ...22 5 7 Using the Modular Smart Switch 24 5 8 Port Indicators 1 to 12 24 5 9 Buffer Status Indicators 25 6 Using the Control Software 26 6 1 Installing the Resident Software 26 6 2 Running the Software...

Страница 5: ...Transfer Software 42 8 3 Transferring Files Between PCs Not Compatible with IBM 42 8 4 General Hints and Tips 43 9 Software Commands 44 9 1 Introduction 44 9 2 Connect Command 45 9 2 1 Selecting a De...

Страница 6: ...Meg Memory SW925A SW925AE includes Main chassis with 6 dual port module slots and 2 memory slots Software disk in 3 5 format Power lead with 115 VAC or 230 VAC plug 5 module blanking plates with fixi...

Страница 7: ...ular Smart Switch contains two memory module slots A and B each of which can be fitted with a 1 MB or 2MB buffer memory module see Figure 3 1 The Modular Smart Switch is supplied as standard with a 1...

Страница 8: ...ed on The buffer memory indicators will flash while the test is in progress and go off when the test is complete If all the channel and buffer indicators come on permanently then the buffer has been i...

Страница 9: ...t Switch The ports on the Modular Smart Switch are configured using a number of option switches situated on the modules In addition to the port configuration the global timeout values can be set using...

Страница 10: ...TPUT Automatic input output detection not guaranteed HIGH port switches LOW port switches 16 MODULAR SMART SWITCH Timeout Period When a user has sent no data for the timeout period the Modular Smart S...

Страница 11: ...matic detection is not guaranteed to work with all equipment so if you experience any problems set the ports as dedicated inputs or outputs 4 3 Setting Serial Port Protocols and Options Protocols For...

Страница 12: ...an existing cable is of the correct type because it has the correct connectors on each end or because it works between two other pieces of equipment Always use the cabling recommended in this manual C...

Страница 13: ...57600 N 8 1 enter NOTE If you are sending plot print data from IBM compatibles using a serial port make sure that your AUTOEXEC BAT includes both the MODE with P option and ADMODE commands relevant to...

Страница 14: ...eak in the transmission for more than the timeout period see Section 4 1 If two or more printers plotters are connected to the Modular Smart Switch you will need the software see Chapter 6 or software...

Страница 15: ...be used can be specified once the software has been invoked using the PC PORT function and so these options are primarily for convenience only Hx H1 default 26 MODULAR SMART SWITCH 6 Using the Control...

Страница 16: ...are as follows H1 selects CTRL ALT SHIFT H2 selects CTRL SHIFT H3 selects CTRL ALT H4 selects CTRL ALT H5 selects LEFT SHIFT RIGHT SHIFT SHIFT can be either the left or the right shift key The selecte...

Страница 17: ...ected the PC port that you wish to use to print data With the dialog box displaying the correct PC port and DESTINATION highlighted press enter A new box will appear as shown below Enter the desired d...

Страница 18: ...main menu NOTE Characters such as line feeds are displayed using an unusual set of non alphanumeric characters ADDER TECHNOLOGY ADMENU DIRECT OUTPUT DESTINATION FILE TRANSFER FUNCTIONS OPTIONS PORT 1...

Страница 19: ...TIONS 34 MODULAR SMART SWITCH 6 9 Using the Functions Menu To enter the functions menu use the up and down cursor keys on the main menu to highlight FUNCTIONS and press enter The functions menu now al...

Страница 20: ...tory on your PC At the DOS prompt type a command in the following format ADMODE COMn baud parity databits stopbits You only need to include a parameter after baud if it needs to be changed from the de...

Страница 21: ...0 19200 4800 9600 19200 38400 57600 38400 57600 parity odd even none O E N N data bits 7 or 8 7 8 8 stop bits 1 or 2 1 2 1 Using the Control Software with Windows Version 3 1 Windows version 3 1 suppo...

Страница 22: ...file transfer software A suitable batch file for Kermit would be as follows ADDER TECHNOLOGY ADMENU DESTINATION DIRECT OUTPUT FUNCTIONS OPTIONS PORT 1 COM1 ESC TO QUIT FILE TRANSFER ENTER TARGET PORT...

Страница 23: ...th your Modular Smart Switch should be used together with file transfer software The control software allows you to increase the baud rate for all normal printing and plotting operations so you can us...

Страница 24: ...and one copy on port 1 of every file sent from the computer issue the following command PM CONNECT 3 2 1 44 MODULAR SMART SWITCH 9 Software Commands 9 1 Introduction The Modular Smart Switch can be c...

Страница 25: ...be switched off With the timeout off the output channel remains constantly dedicated to the input channel until an end of file command see Section 9 4 or a new connect command is sent The timeout rema...

Страница 26: ...ine When the enter key is pressed the screen will display 1 File s copied This indicates that a file name TXT has been created that contains the software command text It is not normally possible to us...

Страница 27: ...pted Data The most common cause of corrupted data when using serial interfaces is a handshake problem If you experience corrupted data when using serial ports check that the protocols set on your equi...

Страница 28: ...TCH 10 7 Merged Printouts If the output from one computer has been printed in the middle of that from another you will probably need to increase the timeout period When no data has been sent from one...

Страница 29: ...control in ve hardware HSIN Input handshake 25 Transmit data ve TXD Output A 2 Connecting to Computers RS 232 Connections RS 232 serial ports on computers tend to vary considerably The standard recom...

Страница 30: ...Printers Most serial printers provide a standard DB25 connector for serial data The required cable wiring is shown in Figure A 3 This wiring configuration is suitable for many popular printers such as...

Страница 31: ...TCH A 5 Connecting to Plotters A wide range of different pin configurations are used on plotter serial ports The following cable can be used for most plotters including those manufactured by Hewlett P...

Страница 32: ...N HSIN TXD TXD HSOUT ve ve ve ve ve ve ve ve Flow control in Transmitted data out Flow control out Received data in 60 MODULAR SMART SWITCH A 7 Connecting to DEC LN03 Laser Printer The LN03 outputs it...

Страница 33: ...16 INIT no connection OUTPUT high 17 SELECT IN no connection OUTPUT low 18 25 SIGNAL GROUND ground ground The cables need to have a DB25 connector for connecting to the Modular Smart Switch If possib...

Страница 34: ...ect from IBM compatibles to the Modular Smart Switch require a 25 pin plug on both ends All lines should be connected straight through that is 1 to 1 2 to 2 etc B 3 Cable to 36 Pin Amphenol Connector...

Отзывы: