SERIAL UPGRADE KIT FOR SERVSWITCH™ AFFINITY

4.2 Configuration

To configure a CPU port on an upgraded ServSwitch Affinity as a serial port, press
left-[Ctrl] [F12] at the keyboard of a user station attached to your Affinity system.
This will bring up the on-screen display. Press the down-arrow key to move the
highlight to the “Configure computers” selection, then press [Enter]. The “Configure
computer” page will appear. Use the up- and down-arrow keys to scroll to the port
you want, then press the right-arrow key once to reach the “Keyboard” column and
press [Enter]. The keyboard-type menu will pop up; it will include serial choices
with a variety of data rates, as shown in Figure 4-1. (At the time of this writing, the
other serial parameters are fixed as 8 data bits, no parity, and 1 stop bit.) Use the
down-arrow key to move the highlight bar to the data rate you want, then press
[Enter]. In the example shown in Figure 4-1, the “Computer 1” port has already
been set to be a 9600-bps serial port, and the “Computer 2” port is about to be.

Figure 4-1. Selections at the “Configure Computer” page after the upgrade.

Configure computer

Use page up and page down keys to configure more computers

Type of computer, for PCs this is the computer’s keyboard mode

Computer Name       Keyboard  Mouse

1 Computer       1    Serial 9600,N,8,1

2

Computer       2    PC2       PS2

3 Computer       3    PC2       PS2

4 Computer       4    PC2       PS2

5 Computer       5    PC2       PS2

6 Computer       6    PC2       PS2

7 Computer       7    PC2       PS2

8 Computer       8    PC2       PS2

9 Computer       9    PC2       PS2

10 Computer      10    PC2       PS2

11 Computer      11    PC2       PS2

12 Computer      12    PC2       PS2

13 Computer      13    PC2       PS2

14 Computer      14    PC2       PS2

15 Computer      15    PC2       PS2

16 Computer      16    PC2       PS2

PC2

PC1

PC2

PC3

USB-PC

USB-Sun

Serial 9600,N,8,1

Serial 4800,N,8,1

Serial 2400,N,8,1

Serial 1200,N,8,1

Serial  600,N,8,1

Serial  300,N,8,1

Serial  110,N,8,1

Serial   50,N,8,1

Serial 9600,N,8,1

Содержание ServSwitch KV130-UPG

Страница 1: ...24 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox...

Страница 2: ...ne of robust solutions for all these applications Do you have just two PCs and need an economical alternative to keeping two monitors keyboards and mice on your desk Or do you need to share dozens of...

Страница 3: ...t off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and rec...

Страница 4: ...ato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las in...

Страница 5: ...u orificios de ventilaci n 18 Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del...

Страница 6: ...e 1 Specifications 6 2 Introduction 7 3 Installation 8 4 Operation 11 4 1 Overview and Cabling 11 4 2 Configuration 12 4 3 The Terminal Display and Scroll Buffer 13 5 Troubleshooting 15 5 1 Calling Bl...

Страница 7: ...TIA RS 232 proprietarily pinned on DB25 Protocol RS 232 Asynchronous Data Format RS 232 8 data bits no parity 1 stop bit fixed Data Rate RS 232 50 110 300 600 1200 2400 4800 or 9600 bps user selectab...

Страница 8: ...in your ServSwitch Affinity system NOTE If you have R3 version Matrix ServSwitches attached to your ServSwitch Affinity system you won t be able to attach serial devices to the Matrix ServSwitches but...

Страница 9: ...he OSD daughtercard and you ll need to call Black Box Technical Support Without messing around with the Affinity s hardware at all you can check the revision level in one of two ways a Cycle power to...

Страница 10: ...where a b c and d are revision numbers If the large right hand chip is labeled with a revision earlier than O4 2 you won t be able to install the Upgrade Kit in the field Please skip the remainder of...

Страница 11: ...mands to switch between the ports if necessary If any switching commands fail make sure that the new chips are seated firmly on the daughterboard and that the Port Card is seated firmly in the slot If...

Страница 12: ...erial Upgrade Kit modifies the OSD firmware to implement VT100 101 102 202 terminal emulation scrolling a hardware cursor cursor controls and other necessary elements to convert and format serial data...

Страница 13: ...o move the highlight bar to the data rate you want then press Enter In the example shown in Figure 4 1 the Computer 1 port has already been set to be a 9600 bps serial port and the Computer 2 port is...

Страница 14: ...figure System page see the Configuring the System section in your Affinity manual Figure 4 2 Screen shot of an Affinity terminal session with a UNIX computer r sr xr x 2 uucp uucp 31258 Aug 14 2001 uu...

Страница 15: ...get a blank screen with the cursor in the upper left hand corner As you interact with the computer the screen fills up with data This data is stored in the Affinity in a separate buffer for each compu...

Страница 16: ...and duration of the problem when the problem occurs the components involved in the problem any particular application that when used appears to create the problem or make it worse and the results of...

Страница 17: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 2002 Black Box Corporation All rights reserved...

Отзывы: