FOM LINE DRIVER—ST AND S M
6
There are three operating modes you can choose from: network mode, master/slave mode, or point-to-
point configuration. In network mode, all of the units are configured. If you want one Line Driver
configured as a master and the others as slaves, you need to be in master/slave mode. Finally, point-to-
point configuration is a full-duplex mode where both FOM Line Drivers are configured as masters.
This chapter describes each scenario in greater detail. Read the entire chapter before deciding which
configuration is right for you.
3.1 Network Mode
In this mode, data sent to the transmitter (TX) of the RS-232 DB9, 20-mA current loop, or RS-485
terminal block is passed out to both optical transmitters (TX).
Data received from either optical receiver (RX) is passed through to the opposite optical port’s
transmitter (TX), to the receiver (RX) of the RS-232 DB9, the 20-mA current loop, or the RS-485 port.
NOTE
There is no collision detection.
Figure 3-1. All units configured in network mode.
As you look at the example above, keep these things in mind.
• In network mode, all of the devices look the same. There are no masters or slaves.
• Data flow is half-duplex only.
• All devices see all data on the network.
TX RX
TX RX
TX RX
TX RX
TX RX
TX RX
TX RX
TX RX
TX RX
TX RX
TX RX
TX RX
TX RX
TX RX
TX RX
TX RX
3. Configurations
Fiber
Cabling
232/485/C. Loop
Receiving
Receiving
232/485/C. Loop
Receiving
Transmitting
232/485/C. Loop
Transmitting
Receiving
232/485/C. Loop
Receiving
Receiving
Data
Path