100
MINI-MODEM (56 KBPS DATA/FAX MODEM)
S6
seconds 2–255
2
Sets the time the
modem goes off-
hook before it begins
to dial the telephone
number.
S7
seconds 1–255
50
Sets the the time the
modem waits for a
carrier signal before
aborting a call. Also
sets the wait for
silence time for the
@ dial modifier.
Reg. Unit
Range
Default Description
S8
seconds 0–255
2
Sets the length of a
pause caused by a
comma character in
a dialing command.
S9
1/10 sec 0–255
6 (0.6) Sets the time, in
tenths of a second,
that the carrier must
be present before the
modem considers it