background image

CUSTOMER

SUPPORT

INFORMATION

Order 

toll-free

in the U.S.: Call 

877-877-BBOX

(outside U.S. call 

724-746-5500

)

FREE technical support 24 hours a day, 7 days a week: Call 

724-746-5500

or fax 

724-746-0746

Mailing address: 

Black Box Corporation

, 1000 Park Drive, Lawrence, PA 15055-1018

Web site: 

www.blackbox.com

•   E-mail: 

[email protected]

MAY 1994

LT098A

LT098AE

LT099A

LT099AE

LT198
LT199

Modular Parallel Adapters

Modular Media Units

Содержание LT098A

Страница 1: ...technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info...

Страница 2: ...is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever m...

Страница 3: ...bricante 7 El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo...

Страница 4: ...l calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvi...

Страница 5: ...pter 12 4 Software Setup and Operation 13 4 1 Supplied Files 13 4 2 Configuration Optional 14 4 3 ODI Driver for Novell NetWare 15 4 3 1 Installation 15 4 3 2 Operation 15 4 4 NDIS Driver for Microsof...

Страница 6: ...Interface Connects to parallel port Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 40 to 176 F 4 to 80 C Memory Size 64K x 16 network buffer Input voltage 12 VDC 500 mA Connectors LT...

Страница 7: ...The modular construction of the Token Ring Adapter enables you to work with either of the two cabling systems used in Token Ring networks you simply attach the Modular Media Unit that matches your ca...

Страница 8: ...nal bidirectional mode selection Supports parallel ports LPT1 through LPT4 Supports interrupt lines IRQ7 and IRQ5 as well as polling mode when no interrupt line is available Power and network activity...

Страница 9: ...rk cable 3 Plug the Token Ring Adapter into the computer 4 Install the AC power adapter Instructions for loading the network drivers and configuring the driver if necessary are provided in Chapter 4 3...

Страница 10: ...Installation 3 2 Connect the Network Cable Connect the network cable as illustrated for each model shown in Fig 3 3 and 3 4 3 2 1 LT099A Fig 3 2 Connecting an Unshielded Twisted Pair Cable to the Medi...

Страница 11: ...DAPTERS AND MODULAR MEDIA UNITS 3 2 2 LT098A After connecting the cable use the captive screws provided on the cable to lock the connector in place Fig 3 3 Connecting a Shielded Twisted Pair Cable to...

Страница 12: ...Computer Plug the 25 pin connector on your Adapter into the parallel port at the back of your notebook laptop computer holding the adapter with the logo at the top Tighten the knobs on the Adapter clo...

Страница 13: ...the AC power adapter into the small round socket at the back of the Modular Media Unit as shown in Fig 3 6 Plug the other end of the AC adapter cable into any standard electrical outlet The red LED w...

Страница 14: ...RDIAG HLP Help file for the diagnostic program The LSP subdirectory contains the following IBM LAN Support Program LSP drivers for use with any network that is compatible with the IBM LSP CPIL EXE Har...

Страница 15: ...mode This mode improves the performance of the Adapter and therefore is recommended if your computer supports it NOTE Be sure that your PC has an Enhanced Parallel Port EPP before selecting the E com...

Страница 16: ...to the network The STARTNET BAT file includes the following set of commands LSL CPIM Parameter 1 Parameter 2 STRODI IPXODI NETX F If you wish you may enter these commands in the AUTOEXEC BAT file in t...

Страница 17: ...rectory as follows copy a ndis cpim exe copy a ndis protocol ini For DOS type copy a ndis strndis dos 6 At the C LANMAN prompt type setup 7 From the main menu select Actions then View Modify Accept th...

Страница 18: ...Support Program The Adapter can emulate an IBM Token Ring adapter in order to be compatible with software designed to work with an IBM adapter 4 5 1 INSTALLATION 1 Copy all files from the LSP subdirec...

Страница 19: ...k directory prompt type the following command strdiag The strdiag command may be entered with special command line parameters as follows U force unidirectional mode C use color display default is mono...

Страница 20: ...pt logic and the connection between the PC and the communication processor The initialization test also tests the internal cable circuitry of the Adapter During operation many Token Ring tests are per...

Страница 21: ...4 VIEW CONFIGURATION FILES This option allows the user to view the contents of the different configuration files NET CFG for Novell ODI and PROTOCOL INI for LAN Manager NDIS If the file is longer tha...

Страница 22: ...stic program to get more information about the problem Modadpt Token Ring Adapter failed to open on ring The adapter failed to integrate within the ring Check that the LAN cable is properly attached t...

Страница 23: ...22 MODULAR PARALLEL ADAPTERS AND MODULAR MEDIA UNITS Additional error messages related to your network operating system are described in the appropriate NOS manuals...

Страница 24: ...e that your Adapter is properly installed powered and connected to the network 2 Run STRDIAG and write down the results of the diagnostics 3 Try to operate your Adapter in unidirectional and polling m...

Страница 25: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 1994 Black Box Corporation All rights reserved...

Отзывы: