Hardware Installation
NOTE: Power cables are shipped separately from the LB52xA-KIT
3.1.6 Connecting cables
1. Connect the Ethernet cable to the Management port. LB52xA-KIT supports audi-
MDIX switching so you may use a crossover or straight-through cable.
2. Connect one end of a phone cable to the LINE port and the other end of the cable
to a wall jack.
3.1.7 Grounding the LB52xA-KIT and connecting power
When connecting to the power source, it is important to establish a good grounding
connection first, and then the power connection. Do the following:
1. Assemble a ground wire using #10 AWG wire with green-colored insulation and
two ring terminals. Make the wire long enough to reach one of the following earth
ground sources:
• The building ground rod (generally located at the site’s main service entrance)
• A sprinkler system pipe
• A cold-water pipe
• Building structural steel
The Interconnecting cables must be acceptable for external use
and must be rated for the proper application with respect to volt-
age, current, anticipated temperature, flammability, and mechani-
cal serviceability.
Do not work on the system or connect or disconnect cables during
periods of lightning activity.
CAUTION
WARNING
Содержание LB522A-KIT
Страница 15: ...724 746 5500 blackbox com Page 15 Applications Overview Figure 4 LB52xA KIT application ...
Страница 71: ...724 746 5500 blackbox com Page 71 Console and Telnet Configuration Figure 61 Menu tree for authorized users ...
Страница 111: ...724 746 5500 blackbox com Page 111 Console and Telnet Configuration ...
Страница 112: ...724 746 5500 blackbox com Page 112 Black Box DeeSL 2 Ethernet Extender ...