APPENDICES
69
Appendix G. Password jumper
If the configuration password is ever forgotten, the ServSwitch Console Plus
switch has a special “Password” reset jumper on the CPU card. This jumper is
labeled JP31 on all models. To use this jumper to bypass the password,
perform the following:
1.
Turn off the ServSwitch Console Plus switch and remove the top cover.
2.
Install a jumper on JP31 to short the two terminals.
The login requirement will be bypassed and you will be granted access. This
does not delete the password, only bypasses the function.
3.
Power on the ServSwitch Console Plus with the jumper in place.
4.
Call up the main menu; select “System” and press [Enter].
5.
Select “Configure password” from the configure system menu and press
[Enter].
6.
Enter a new configuration password and press [Enter].
7.
Save the new configuration password from the “Main Menu”.
8.
With the new password saved, turn off the ServSwitch Console Plus switch.
9.
Remove the jumper on JP31.
10.
Re-install the top cover.
11.
Turn the ServSwitch Console Plus on. The ServSwitch Console Plus switch
will boot up and the new password will be effective.