SERIAL CONTROL PORT
57
Option 4. Send this Unit’s Main Program to other Units.
Option 5. Send this Unit’s Kernel to other Units.
The main program or kernel program updates (Option 3) only have to be done
on one port. Make sure power to all switches is “ON” and they are all
connected using the appropriate expansion cables.
Press 4 to send the main program to all other units, all other cards.
Press 5 to send the kernel program to all other cards.
The following messages will appear using either option 4 or option 5.
Before responding Y, make sure that the “Boards to update” number in the
message above agrees with the total number of boards in the entire system
minus 1. If the number does not agree, reply N, turn on the inactive units, and
press 4 or 5 again. When you reply Y, the following message appears:
When complete, the system returns you to the serial options menu. Wait at least
15 seconds before restarting the ServSwitch Console Plus after choosing option
4 or 5 for the program to propagate to the other cards in the system.
Option 6. Reset to Factory Defaults (This CPU card only)
NOTE: Before resetting any CPU card to factory defaults, note the starting
computer number listed on the Serial menu, Option 1. When resetting a CPU
card to factory defaults, this number will be set to one (1) and must be changed
back to the original value by using option 1 to change the starting computer
number and then saved using option 7. In an expanded system, there cannot
be two different ServSwitch Console Plus switches in the system with the same
starting computer number.
Selecting option 6 restores the CPU card to its original factory configuration.
The following message appears:
When the factory defaults have been restored, the following message is
displayed:
The serial options menu is then displayed, indicating that this CPU board has
been reset to the factory defaults.
Boards to update - n
You are about to copy the firmware from this board to all other boards in
the system.
Are you sure? Y/N
Sending flash program code to system........................
Flash programming . . . . . . . . . . . . . . . . . . . .
Reset to default successful