Chapter 5: Maintenance

5. Maintenance

1. Clean the fiber connector and the connecting flange on a regular basis.

2. Use standard fiber connectors when testing.

3.  When the unit is not in use, place the dust cap on the connector to prevent it 

from being scratched or becoming dirty.

4.  Make sure that the operating voltage of the AC adapter/charger is the same as 

the local AC line voltage.

5.  To eliminate the possibility of acid leakage, remove the batteries if the unit will 

not be used for a long time.

Содержание FOOBL

Страница 1: ...imple to operate Optical Break Locator Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com Customer Support Information FOOBL ...

Страница 2: ... void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emis sion from digital apparatus set out in the Radio Interference Regulation of Industry Canada Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le...

Страница 3: ... operación o como se indique en el aparato 12 Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada 13 Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos poniendo particular atención a los contactos y receptáculos donde salen del aparato 14 El equipo elé...

Страница 4: ...pter charger terminal and the batteries Excessive electrical current may cause personal injury due to fumes electric shock or equipment damage Connect the AC power cord to the equipment and wall socket properly When you insert the AC plug make sure there is no dust or dirt on the terminals and both plugs are fully seated WARNING If the AC plug is not connected properly fuming electric shock or equ...

Страница 5: ...1 Parts of the Optical Break Locator 9 4 2 Key Functions 10 4 3 LCD 11 4 4 Before Using the Optical Break Locator 11 4 5 Using the Keys 11 4 5 1 Group Refractive Index Setting 12 4 5 2 Test Operation 12 4 5 3 Test Result Checking 12 4 5 4 Reading Data from a PC 12 4 5 5 Using the AC Adapter 12 5 Maintenance 13 Appendix Troubleshooting 14 A 1 Problems Causes Solutions 14 A 2 Calling Black Box 15 A ...

Страница 6: ...0 mW Type of Event Refractive event Maximum Measuring Distance 80 7 miles 130 km Measuring Accuracy 0 8 m 0 001 x measuring distance Measuring Dead Zone 9 6 ft 3 m Connectors PC interface 1 Mini USB Temperature Tolerance Operating 4 to 122 F 10 to 50 C Storage 4 to 140 F 20 to 60 C Humidity Tolerance 0 to 85 noncondensing Power 5 VAC adapter or 4 AA batteries Size 4 5 H x 2 5 W x 1 2 D 11 4 x 6 4 ...

Страница 7: ...o operate Use it for fiber installation detection and maintenance 2 2 What s Included Your package should include the following items If anything is missing or damaged contact Black Box Technical Support at 724 746 5500 Main unit Quality check report Carrying case 2 NiMH batteries type AA This user s guide on CD ROM 2 3 Features Small compact unit is lightweight and is easy to carry Reliable high ...

Страница 8: ...acid from leaking 3 2 AC Operation If you will use the unit mainly at one location for example in a laboratory or test department use the AC adapter to power it instead of batteries The unit has a DC input jack on the left side of the tester Plug the AC adapter s output cable in there When the AC adapter is plugged in the AC indicator on the LCD will be displayed NOTES 1 Power is supplied by the A...

Страница 9: ...he instrument panel is divided into two parts the LCD display and the operation keys The unit has an FC PC fiber connector LCD display Operation keys 5 6 1 3 2 7 4 FC connector interchangeable Figure 4 1 The Optical Break Locator 4 2 Key Functions The Optical Break Locator s keys are described in Table 4 1 ...

Страница 10: ...Press this key to exit the current working states 3 Test Press this key to start a test 4 Backlight Press this key and release it in less than two sec onds and the backlight will turn on But if you don t press another key within 30 seconds the backlight will automati cally turn off To deactivate the auto off function for backlight press the key for longer than three seconds 5 OK Press to confirm t...

Страница 11: ...tteries need to be recharged use the charger 3 Cover the fiber connector with the protective dust cap when it is not in use 4 Do not connect the laser source to this instrument directly Optical sensors might be damaged 5 Make sure the test fibers are securely connected before testing You can t pull out the fiber during testing because the refractive effects may damage the instrument WARNING Do not...

Страница 12: ...ng when you press the TEST button The laser icon stops blinking when the test is complete It then displays the test result in meters The M blinks Press OK to save all the data to the current position or press LEFT key to enter the storage option position Press the UP or DOWN button to choose the new save position then press OK to confirm During the test press the CANCEL key to exit the setting mod...

Страница 13: ...r connectors when testing 3 When the unit is not in use place the dust cap on the connector to prevent it from being scratched or becoming dirty 4 Make sure that the operating voltage of the AC adapter charger is the same as the local AC line voltage 5 To eliminate the possibility of acid leakage remove the batteries if the unit will not be used for a long time ...

Страница 14: ...attery 4 If the unit still doesn t work return it to Black Box for details see Section A 2 Problem The unit goes on and off sometimes but not always Possible Cause Low battery Solution Charge the battery or use the AC power supply Problem Measurement is not accurate Possible Causes 1 The connector is contaminated 2 The connector does not fit properly Solution 1 Clean the dust from the connector wi...

Страница 15: ...hnical Support at 724 746 5500 Before you do make a record of the history of the problem We will be able to provide more efficient and accurate assistance if you have a complete description including the nature and duration of the problem when the problem occurs the components involved in the problem any particular application that when used appears to create the problem or make it worse A 3 Shipp...

Страница 16: ...m About Black Box Black Box Network Services is your source for more than 118 000 networking and infrastructure products You ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 20 seconds or less Copyright 2010 All rights reserved FOOBL rev 1 ...

Отзывы: