41
CHAPTER 5: Programming the ASD-4
Table 5-2: The ASD-4’s Custom Functions (Multi-Value Options)
1. Access the programming mode by pressing [#] [*] at a local phone or the Security
Access Code at a remote phone.
2. Change function settings by entering the function number, followed by a valid
entry from the settings available:
FUNCTION
FACTORY
OPTIONS
SETTING
AVAILABLE
[2][1]
Security Access Code
[1] [2] [3] [4]
any 1 to 4 digits
[2][2]
FAX Access Code
[1] [1]
any 1 to 4 digits
[2][3]
MODEM Access Code
[2] [2]
any 1 to 4 digits
[3][1]
TAD and PHONE Ports’
[1]
[0] OFF
Distinctive Ring
[1] 1-burst ring
[2] 2-burst ring
[3] 3-burst ring
[3][2]
FAX Port’s Distinctive Ring
[2]
[0] OFF
[1] 1-burst ring
[2] 2-burst ring
[3] 3-burst ring
[3][3]
MODEM Port’s Distinctive Ring
[3]
[0] OFF
[1] 1-burst ring
[2] 2-burst ring
[3] 3-burst ring
[4][0]
Rings to Answer Call
[1]
[1] to [9][9]
[4][1]
Rings Available to
[6]
[0] to [9][9]
TAD and PHONE Ports
[4][2]
Rings Available to FAX Port
[3]
[1] to [9][9]
[4][3]
Rings Available to MODEM Port
[3]
[1] to [9][9]
[5]
Phantom Ring Style
[1]
[1] to [7] (see
Section
5.4.11
)
[6]
Automatic TAD-Transfer Timer
[3][0] seconds
[0] to [9][9] seconds
[7]
RMN Phone Number
none
any phone number
up to 16 digits long
[8]
RMN Conditions
[1]
[1] TAD
[2] FAX
[3] MODEM
[9][9][9]Reset to Factory Settings
the values in
Tables 5-1 & 5-2
3. End your entry by pressing [*]. Make as many entries as you need.
4. Exit the programming mode by pressing [*] again.