JANUARY 2001

AC455A-TX-R2

AC456A-RX-R2

Fiber Link—Transmitter

Fiber Link—Receiver

POWER

+12~16VDC

ALARM/+5VDC

GROUND

3

2

1

AC/DC+

GROUND/DC-

AC

3

2

1

FIBER

VIDEO IN

Содержание AC455A-TX-R2

Страница 1: ...a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mail order Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com JANUARY 2001 AC455A...

Страница 2: ...Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the i...

Страница 3: ...o el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las inst...

Страница 4: ...una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuidado debe...

Страница 5: ...4 FIBER LINK TRADEMARKS USED IN THIS MANUAL Any trademarks mentioned in this manual are acknowledged to be the property of the trademark owners...

Страница 6: ...res 10 3 Installation 12 3 1 Physical Installation 12 3 2 Signal Connections 13 3 3 Optical Connections 14 3 4 Power Connections 14 3 5 System Power 15 4 Transmitter and Receiver Optical Indicators 16...

Страница 7: ...5 Signal to Noise Ratio 54 dB at maximum optical attenuation Video Bandwidth 10 Hz to 10 MHz Video Resolution 800 TV lines Differential Phase 3 Differential Gain 3 Tilt 0 Input Coupling Capacitative O...

Страница 8: ...to 2 V Genlock Sync Signal Sync Direction RX TX Detection Area Can be imposed on all lines outside the control area Sync Amplitude Up to 6 V Optical Wavelength 850 and or 1300 nm Optical Mode Multimod...

Страница 9: ...Radiated Pulsed Magnetic Field Immunity Product Safety No standards required since the Fiber Link is DC powered by SELV Safety Extra Low Voltage Controls Alarm Disable Removable jumper on receiver car...

Страница 10: ...power to heat The actual heat generated will be less Environmental Temperature Operating 32 to 122 F 0 to 50 C Storage 40 to 185 F 40 to 85 C Mechanical Enclosure Transmitter 4 x 4 10 x 10 cm Receive...

Страница 11: ...erent wavelengths 850 and 1300 nm for two way transmission The control signals are transmitted during the vertical blanking period of the video signal In addition to video and control the Fiber Link p...

Страница 12: ...11 FIBER LINK Figure 2 1 Typical Application One coaxial cable One coaxial cable One fiber Transmitter Receiver Video and response Video and response...

Страница 13: ...the module and make sure that there s adequate space at both ends for making various cable connections and reading the diagnostic LEDs 2 The Fiber Link has mounting holes for four No 6 screws 3 mm sc...

Страница 14: ...back to electrical signals for output at the receiver The electrical signal connections to the Fiber Link consist of a single BNC connector on the transmitter and receiver CAUTION Make sure all the pe...

Страница 15: ...ndalone modules are equipped with removable screw terminal connectors for power input 1 Identify the power connector and remove it from the module 2 Make sure the power supply is not connected to any...

Страница 16: ...ent You ll need to verify system operation You can do this by observing video on the monitor at the receiver end or by operating all of the pan tilt zoom functions controlled by the up the coax data s...

Страница 17: ...als When a valid signal is being transmitted or received the VIDEO LED will glow green if no signal is present the LED will glow red A Red VIDEO LED suggests that the camera is either off or inoperati...

Страница 18: ...deo signal received Check the camera and coax Check the LEVEL LOSS indicator If the LEVEL LOSS indicator is green check the video indicator on the TX unit COMMAND Green Indicates PTZ command transmiss...

Страница 19: ...18 FIBER LINK Figure 4 1 End View of Standalone Module COMMAND OUT RESPONSE IN SYNC OUT VIDEO IN LEVEL LOSS...

Страница 20: ...de AC455A TX R2 AC456A RX R2 of the Fiber Link A listing of the diagnostic indicators and their respective color condition 5 2 Calling Black Box If you determine that your Fiber Link is malfunctioning...