Operations
54
4.12 Save and Recall Operation
The stored settings of all channels can be recalled. The stored parameters include operation mode, voltage/current
values, slew rate, transient setting, and more. Up to 101 groups of setting parameters can be saved. Group 0 can be
used for power-up settings. Groups 1 through 100 can be used for automatic testing parameters. All parameters are
saved into non-volatile memory and will remain saved even in a powered down state.
To save the channel’s settings:
1. After setting up your parameters, press the
key to save. It will ask for the Save Group number.
2. Input the Save Group number (0-100) and press
to confirm.
To recall previously saved settings:
1. Press the
key. It will ask for the Recall Group number.
2. Input the Group number (0-100) you previously saved your parameters to and press
key to recall.
4.13 Module Controlling Link
There is an 8-pin terminal and current monitoring connector on every module’s rear panel.
Figure 4.16
Single-Channel Control Module Link