BK Precision CP62 Скачать руководство пользователя страница 1

 

 

 

1

 

 

 

 
 
 
 

 
 
 
 
 
 

 

 

Model:  CP62 

DC – 100 A Current Probe

 

USER MANUAL 

 

 

www.

.com

[email protected]

1.800.561.8187

Содержание CP62

Страница 1: ...1 Model CP62 DC 100 A Current Probe USER MANUAL www com information itm com 1 800 561 8187...

Страница 2: ...nditions even with the power cable removed dangerous voltages may exist To avoid injuries always disconnect power and discharge circuits before touching them DO NOT SERVICE OR ADJUST ALONE Do not atte...

Страница 3: ...cipal waste Please utilize your local WEEE collection facilities in the disposition of this product and otherwise observe all applicable requirements Safety Symbols Terms in This Manual These terms ma...

Страница 4: ...ctromagnetic Compatibility Directive with the following standards Low Voltage Directive EN61010 Safety requirements for electrical equipment for measurement control and laboratory use EMC Directive EN...

Страница 5: ...ble 1 3 5 Certifications and compliances 9 2 INSTALLATION 11 2 1 Introduction 11 2 2 Package Contents 11 2 4 Signal Connections 11 3 OPERATING INSTRUCTIONS 12 3 1 General Description 12 3 2 Controls a...

Страница 6: ...ory TL62 BNC to banana plug adapter 1 3 Specifications Table 1 3 0 Electrical Characteristics Current Ranges 10 100 mV A DC Accuracy typical 3 50 mA at 100 mV A 50 mA to 10 A peak range 4 50 mA at 10...

Страница 7: ...ironmental Characteristics Temperature Working Storage 0 C to 50 C 32 F to 122 F 20 C to 80 C 4 F to 176 F Humidity 0 C to 40 C 95 humidity 40 C to 50 C 45 humidity Pollution Degree 2 Table 1 3 4 Powe...

Страница 8: ...CP62 Operating Manual 8 Figure 2 Maximum current versus frequency Figure 3 DC signal linearity in the 10 mV A range typical www com information itm com 1 800 561 8187...

Страница 9: ...d by 93 68 EEC EN 61010 1 A2 1995 Safety requirements for electrical equipment for measurement control laboratory use EN 61010 2 032 1995 Particular requirements for hand held current clamps for elect...

Страница 10: ...l environment inside a product is considered to be the same as the external Products should be used only in the environment for which they are rated Pollution Degree 1 No pollution or only dry noncond...

Страница 11: ...ring transportation Report any damage to the shipping agent immediately Save the original packing carton for possible future reshipment Every generator is shipped with the following contents CP62 Curr...

Страница 12: ...connectors of the current probe 1 Power Range Switch Power ON OFF select 10mV A or 100mV A range 2 DC Zero Offset Knob 3 Clamp Max 11 mm Wire 4 Clamp Lever Opens jaw 5 Battery Compartment Located ins...

Страница 13: ...on and the green battery indicator lights If the indicator does not light see Battery Notes and Battery Installation on page16 Battery indicator The green battery indicator lights when the probe is t...

Страница 14: ...obe The CP62 current probe has a green LED power battery indicator If the LED does not light replace the battery or use specified power adapter 3 Use the ZERO adjustment to zero or offset the probe ou...

Страница 15: ...AC volts To measure DC current set the meter to measure DC volts Note the current convention arrow on the probe to get the proper polarity reading 3 4 3 Increase Sensitivity To increase the measuremen...

Страница 16: ...n using an AC power adapter for an extended time we suggest you remove the battery from the compartment This is because overheating may cause battery leakage which may damage circuitry It is safe to p...

Страница 17: ...e jaw and clean the exposed core surfaces with a cotton swab dampened with isopropyl alcohol Lubricate the jaws mating surfaces with light oil Do not clean with solvents or abrasives Do not immerse th...

Страница 18: ...an shipping fees please contact B K Precision Corp Include with the returned instrument your complete return shipping address contact name phone number and description of problem LIMITED ONE YEAR WARR...

Страница 19: ...2014 B K Precision Corp v063014 www com information itm com 1 800 561 8187...

Отзывы: