29
Figure 13 – Parallel Mode Wiring for All Channels
2.
Verify all wiring is connected as illustrated.
3.
Power on the unit and verify that the outputs are turned off (On/Off
button not
illuminated).
4.
From the
Power Combine Set
… menu, select
Para
and press the
button.
5.
The following options are available:
CH1+CH2, CH1+CH3
or
ALL
.
6.
Select
ALL
and press the
button.
The power supply will display
Parallel
Successful!
Figure 14 - All Channels Parallel Display
4.13
Tracking Mode
This function configures the channels for tracking mode. In tracking mode, when a voltage or
current parameter is changed, channels change according to the ratio between channels.
1.
From the
Power Combine Set
… menu, select
Track
and press the
button.
2.
Select one of the following:
CH1+CH2
,
CH1+CH3
or
ALL
. Then, press the
button.
The power supply will display
Track Set Successful!
The
symbol will appear on the
display to indicate tracking is enabled.