Serial Trigger and Decode
121
Figure 10.57
SENT Message3
–
Error
: the oscilloscope triggers on the error frame. Errors include Successive Sync Pulses Error Pulse Period
Error, Fast Channel CRC Error, Slow Channel CRC Error, All CRC Errors.
–
Successive Sync Pulses Error: triggers on a sync pulse whose width varies from the previous sync
pulse’s
width
by greater than 1/64 (1.5625%, as defined in the SENT specification).
–
Pulse Period Error: triggers if a nibble is either too wide or too narrow (for example, data nibble < 12 (11.5)
or > 27 (27.5) ticks wide). Sync, S&C, data, or checksum pulse periods are checked.
–
Fast Channel CRC Error triggers on any Fast Channel Message CRC error.
–
Slow Channel CRC Error triggers on any Slow Channel Message CRC error.
–
All CRC Errors triggers on any CRC error, Fast or Slow.
10.10.3
SENT Serial Decode
Once the setup for the SENT signal and trigger has been completed, the decoding operation must be setup.
1.
Touch Decode key to display the
Decode
menu.
2.
Use the touchscreen to enable the
Bus Operation
.
3.
Touch
Bus
to select either
Bus1
or
Bus2
.
4.
Touch
Display
to select the character encoding format of the
decoding’s
result.
–
The
bus’s
vertical position can be adjusted using the
after selecting
Bus Position
.
–
Touch
Format
to set the format of the bus. (Default: Hexadecimal)