BJLive Enabler 9R Скачать руководство пользователя страница 1

BJ-237  

Enabler 9R

       

User guide

 

 

 

 

 

 

       

     

         

                      

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                  

www.bjliveat.com

 

 

 

 
This enabler with nine relay switched contacts is designed to 

control up to 9 functions of the same element or of different 

elements:  lifts,  ceiling hoists,  elements in a sensory room, 

etc.  
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 1: BJ Enabler 9R  

 

You can activate the enabler remotely using any of the BJ 

System’s remote controllers. 

 

 

 

 

 

 

RF Frequency 

433MHz 

Power supply 

12-24 Vdc / 12Vac 

Output 

9 relay contact 

Size  

105 x 59 x 36 mm. 

Minimum section of the power 

cables 

0.5 mm2 

Maximum section in load circuit  

1.5 mm2 

Maximum resistive loads: 

1A - 24Vdc 

1A - 24Vac 

Not compatible with 230 V ac loads 

 

 

 

 

 

For correct installation, the enabler must be fitted in a sealed 

box that provides sufficient space, absence of dust and 

humidity and isolation from direct contact with people. 

 

The dimensions of the box where it is installed must be at 

least: 120mm x 100mm x 48mm (length, width, height). 

It can be fitted on the surface or recessed.   The enabler 

has two “anchoring holes” for fitting (Fig. 1). The distance 

between the anchoring holes is 105mm and the holes’ 

diameter is 4mm. 

 

To install the enabler you must carry the enabler’s power 

cable and load cable’s to the box where it will be installed. 

 

 

 

 
 
 
 
 
 
 
 
 
 
For a proper installation of the device see figure 2: 
 

 

 

     Fig. 2: Circuit diagram of the Enabler connections 

 

 

 

 

 

 

 

 

IMPORTANT!: 

See the device technical data to check 

the type and maximum loads that can be connected 

to the enabler.  

 

Power cables must be stripped a distance of 5mm. 

 

Once the enabler’s connections are made and before 

connecting the device to the power supply, you must 

choose the position on the “RF code selector” (see figure 

1). 

NO

C

NO

C

NO

C

NO

C

NO

C

NO

C

NO

C

NO

C

NO

C

1. Description of the Device

 

2. Technical data

 

3. Pre-installation

 

4. Installation

 

CAUTION! 

Electrical installation may only be 

carried out by a qualified electrician! 

Do not make any unauthorized alterations or 

modifications to the unit. 
The relay contact is only suitable for 

low voltage 

power supply 

(24 V dc/ac – 1A) 

Observe the manufacturer’s instructions for the 

device to be operated. 

 

CAUTION!: 

An error in the connections may cause 

serious damage to the device or the installation, 

or harm to the operator. 

 

Power supply 

terminal 

Relay’s 

terminal 

Jumper 

Anchoring  

hole 

RF code 