RFID Programming Manual
Ver.01.10
- 32 -
7-6 Secured Writing (Unlock & Write)
1) Commands
>RFZ, '00000000, 00000000, 33333333, 33333333' → Access/Kill Password Modification
>RFUL → Unlocking Locked Kill, Access, and EPC Data to Facilitate Writing
T56, 32, 4, 1, 1, 0, 0, N, B, 'RFID Unlock and Write Test '
T57, 81, 2, 1, 1, 0, 0, N, N, 'RFID Data: 01 01 01 01 01 01 01 01 01 01 01 01'
>RFES96,'8,8,8,8,8,8,8,8,8,8,8,8'
>RFW, E, '1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1'
→ EPC Data Writing
T59, 351, 4, 1, 1, 0, 0, N, B, '* Complete *'
P1
2) Printed Label
3) RFID Transponder Data
: 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01 0x01
(Hexadecimal 12 byte)
RFID Unlock and Write Test
RFID Data : 01 01 01 01 01 01 01 01 01 01 01 01
* Complete *