DB-200-6
34
– standard design: cast iron EN-GJL-250 or carbon
steel P265GH
– seawater resistant design: additionally plastic-
coated
3.4
Explanation of model designation
Example
K
1053 H B P - 4
Shell and tube condenser
K
1053
H B P - 4
Construction size
K 1053
H
B P - 4
Fixing brackets
N = only at the bottom
H = at the bottom and the top for single compressor
design (semi-hermetic)
T = at the bottom and the top for single and tandem
compressor design
K 1053 H
B
P - 4
Seawater resistant design
K 1053 H B
P
- 4
Special equipment version for the application with hy-
drocarbons, e. g. for the refrigerant R290: propane
Identification letter is only present if this characteristic
has been selected.
Also possible:
K 1053 H B
C
- 4
Customised version
Identification letter is only present if this characteristic
has been selected.
Special equipment versions for the application with
hydrocarbons can not be customised.
K 1053 H B P -
4
Number of coolant passes
4 = 4 passes
2 = 2 passes
3.5
System registration
Observe the local regulations. The BITZER shell and
tube condensers are considered as pressure vessels
according to the Pressure Equipment Directive
2014/68/EU in the EU. For this reason the entire sys-
tem must be registered and approved by the supervis-
ory authority according to the local regulations. In Ger-
many, for example, the Industrial Safety Regulation
(BetrSichV) is valid additionally, which requires an in-
spection before commissioning and during operation
periodic inspections.
3.6
EU conformity assessment category
according to 2014/68/EU (PED)
Model
In-
ternal
volume
dm
3
(l)
Cat-
egory
with
fluid
group
2
Cat-
egory
with
fluid
group
1
Module
K033N/H(B)(P) 3,8
I
II
A2
K073H(B)(P)
3,4
I
II
A2
K123H(B)(P)
5,1
I
II
A2
K203H(B)(P)
11,8
II
III
B + D
K283H(B)(P)
11,3
II
III
B + D
K373H(B)(P)
14,5
II
III
B + D
K573H(B)(P)
29,4
II
III
B + D
K813H(B)(P)
27,7
II
III
B + D
K1053H(B)(P)
40,0
III
IV
B + D
K1353T(B)(P)
37,0
III
IV
B + D
K1973T(B)(P)
76,0
III
IV
B + D
K2923T(B)(P)
67,0
III
IV
B + D
K3803T(B)(P)
108,0
IV
IV
B + D
K4803T(B)(P)
98,0
IV
IV
B + D
K6703N/T(B)
201
IV
IV
B + D
K8503N/T(B)
181
IV
IV
B + D
Tab. 1: Conformity assessment: category and final assessment mod-
ules
The internal volume is given for the refrigerant side.