Bitspower DDC 4.2 Pump PWM
instruction manual
V2
Dimension
Installation
Troubleshooting
If the pump doesn't operate, please replug the pump in several
times until it works normally.
If it still doesn't work, it is probably blocked by particles.
Drain the system and remove the pump housing. Open the pump
by removing the four housing screws at the bottom.
Remove the housing and pull out the rotor.Clean the rotor with a
clean cloth and purge all dirt from the pump housing.
Vertical
Dimension In:mm
Not permitted Upside down
PWM+TACH cable
POWER cable
Horizontal
SPECIFICATION
Max. flow
9.6 LPM
Max. head
4.34 M
Rated voltage
12V DC
Rated current
1.33 A
Power consumption
16 W
Noise level
≦ 40dBA
Max. temperature
70° C
Notice
You can connect the PWM+Tach cable to any fan slot on the motherboard. And then the speed of the pump can be controlled by the fan PWM function. If not,
there will be no PWM and data display function.
The power cable should connect to the power supply to make the pump work.
If you only connect the Power Cable to the power supply, the pump will run at full speed.
1
2