The StreamSync Acquisition Engine
V_ACQUIRED
Version A.0
BitFlow, Inc.
CYT-2-29
V_ACQ_COUNT
R/W, V_ACQUIRED[15..0], Cyton-CXP
Returns the total number of volumes (frame sequence) acquired since the last reset of
this register. The behavior of this register when it reaches it maximum value depends
on the register V_ACQ_COUNT_CLEAR_MODE. This register can be written to 0 by
software at any time.
V_ACQ_COUNT_
CLR_MODE
R/W, V_ACQUIRED[29..28], Cyton-CXP
Controls how the V_ACQ_COUNT register is cleared.
V_ACQ_COUNT_CLEAR_MODE
Meaning
0 (00b)
Clear count on the start of acquisition
1 (01b)
Clear count on the start of V Window
2 (10b)
Clear count on the start of Z Window
3 (11b)
Clear count on the start of Y Window