4 Installation
4.1 General
General rules:
- Always work with cable glands
- Be careful when drilling, so that the wiring cannot be damaged
- The wiring is not heat resistant, so do not place against hot parts
- Be careful that no cable gets stuck
- Be careful that no cables are in the path of moving parts
4.2 Groundwire
Connect the groundwire directly to the tank. If possible mounted under a bolt,
which keeps the pump in place.
4.3 Power supply
Connect the main power of the AutoFill to the incomming voltage of the hotmelt
unit. Preferably connect to the power behind the mainswitch.
4.4 Ready contact
Connect the brown and blue wire to the ‘ready’ signal from the hotmelt unit.
Use the grey and black wire for the release contact of the machine.
If the pins for the blue and brown wire are already in use, disconnect these two
wires and connect them to the grey and black wire by the thermoplastic
connector.
4.5 Alarm contact
optional.
The + from the transformer has to be connected to NO by the Alarm connector.
The – from the LED/ Siren has to be connected to the – from the transformer.
The + from the LED/ Siren has to be connected to the ‘C’ by the Alarm connector.
Following work is only to be carried out by qualified personnel.
Beware of hot surface
Disconnect the power plug of the hotmelt application before opening!