2. Overview 

2.1 Display overview 

 

Figure 1

 

 
 

Description 

Function 

LED Sensor 

Is lit if level is ok 

LED Hand 

Is lit when turned on manual 

Button Hand 

Manual control  

LED Alarm 

Is lit when there is more than 1 minute ‘output’ 

LED Output 

Is lit when 24V/DC is send to air valve 

LED Auto 

Is lit when turned on automatic 

Button Auto 

Automatic control, also reset 

Main switch 

On/ Off switch  

 
 
 
 
 
 
 
 

Содержание AutoFill V2

Страница 1: ......

Страница 2: ...3 2 Overview 4 2 1 Display overview 4 2 2 Board overview 5 3 Safety symbols 6 4 Installation 7 4 1 General 7 4 2 Groundwire 7 4 3 Power supply 7 4 4 Ready contact 7 4 5 Alarm contact 7 5 The sensor 8...

Страница 3: ...tower 1 Airfilter 1 Control Box 1 4 0m granulate hose with a venturi and 10mm air tube 1 Hose clamp 1 Washer levelsensor 2 Allen head screw M6 x 16 1 Set of electrical components Optional Vibrating el...

Страница 4: ...Sensor Is lit if level is ok 2 LED Hand Is lit when turned on manual 3 Button Hand Manual control 4 LED Alarm Is lit when there is more than 1 minute output 5 LED Output Is lit when 24V DC is send to...

Страница 5: ...4 Alarm Alarmsignal to e g siren alarmlight 5 Supply low 6 Release in Ready signal from hotmelt unit 7 J3 Sensor connector 8 J8 Ground Ground Figure 3 Description Function 1 Dipswitch 1 Calibrate leve...

Страница 6: ...f burning Appliance parts have a high operation temperature Caution high voltage This type of work can only be carries out by qualified personal Caution possible danger of uncontrolled release leakage...

Страница 7: ...Preferably connect to the power behind the mainswitch 4 4 Ready contact Connect the brown and blue wire to the ready signal from the hotmelt unit Use the grey and black wire for the release contact of...

Страница 8: ...AutoFill V2 T 0031 0 348 563 839 W www bithotmelt com 8 5 The sensor 5 1 Adjust the levelsensor Figure 4...

Страница 9: ...at the sensor is at least 40mm in the adhesive Step 5 Wait at least 5 minutes for the sensor to reach the adhesive temperature The range in the sensor is 5mm from the bottom of the sensor till 20mm fr...

Страница 10: ...n valve Step 8 Fasten the filltower to the synthetic base Wait at least 5 minutes to ensure that all liquid adhesive is dript of the sensor Step 9 Press button auto Low level is now saved Calibrating...

Страница 11: ...ked with glue then it is possible that the air can t get out of the system Overpressure can be a consequence Important check and clean both filters regularly Between filltower and synthetic base there...

Страница 12: ...2 Control unit 25 203 0004 1 3 Cable gland M12 75 003 0001 4 4 Air valve 2 2 24V DC 03 001 0050 1 5 Synthetic base 1 1 6 Washer 25 008 0002 1 7 Levelsensor V2 incl cable gland M12 25 202 0002 1 8 Mai...

Страница 13: ...ill V2 T 0031 0 348 563 839 W www bithotmelt com 13 Figure 6 Side view AutoFill Description Partno QTY 12 Filltower AutoFill 25 006 0003 1 13 Mounting bracket 25 008 0005 1 14 Bolt M5x10 2 15 Bolt M6x...

Страница 14: ...07 0002 1 4 Venturi 25 007 1001 1 Figure 8 Mainboard Figure 9 Transformer 24V DC Artikelomschrijving Artikelnummer Aantal Container 120L with window blue standard not shown 25 004 1001 1 Mainboard Aut...

Страница 15: ...w the venturi immediately starts to transport the granulate Sensor does not respond Take the sensor out of the glue Wear a glove and grab the sensor by the range see figure 4 Does the sensor responds...

Отзывы: