AutoFill V2
T
0031 (0) 348 563 839
8 Troubleshooter
Problem
Possible cause
Solution
Alarmlamp lights up.
(reset alarm with AUTO-
button)
Venturi does not transports
granulate.
Shake the granulate loos in the container.
Sensor does not respond
Take the sensor out of the glue.
Wear a glove and grab the sensor by the
range
(see figure 4).
Does the sensor responds now?
Then please calibrate again. (see chapter 5).
Does the sensor not respond, then check the
connection with the mainboard.
Filltower is full with
granulate
Air supply connected at the
output instead of the input at
the air valve
It might be that the air supply and the
output hose are mixed up.
In this way the air valve will open. Now the
venturi immediately starts to transport the
granulate.
Sensor does not respond
Take the sensor out of the glue.
Wear a glove and grab the sensor by the
range
(see figure 4).
Does the sensor responds now?
Then please calibrate again. (see chapter 5).
Does the sensor not respond, then check the
connection with the mainboard.
Air leakage by air valve
Air supply connected at the
output instead of the input at
the air valve
It might be that the air supply and the
output hose are mixed up.
In this way the air valve will open.
Hotmelt system does not
apply glue
Tank is compleet filled with
granulate. So many hotmelt
adhesive is applied. The tank
can not melt fast enough.
Place the washer a little bit lower at the
sensor.
So that the range of the sensor is higher in
the tank.
After re-positioning the washer/ sensor
calibrate the AutoFill again (see chapter 5).
If possible raise the temperature of the tank/
manifold.