background image

BT-410F and BT-410A Operation manual

 

P/N:410-ENG-OPM-EUR-R12 

Bistos Co.,Ltd. 

2021,05 

           

 

Fig. 2.4 Astral Lamp Assembly 

 

3 Operations

 

3.1 Adjust the headband 

Adjust the height and size of headband to fit the user’s head.   

 

3.2 Turn on the power 

Press the power button to turn on the light. The power button is push lock type. It remains lock in when 
pushed. Press the button smoothly until it locked. 
Battery  charging  status  will  be  displayed  by  LED  light.  If  the  LED  turns  to  orange  light,  please  charging 
immediately for further use. 

   

WARNING

 

  Do  not  charge  the  light  while  turned  on.  The  high  charging  voltage  may  cause  the  device 

malfunction. 

 

3.3 Focusing the light (BT-410F only) 

You  can  adjust  the  focal  length  between  25~30  cm.  Adjust  the  focus  for  the  best  light  quality  before 
treatment and examination. 

 

CAUTION

 

  Do  not  glare  the  light  directly  to  the  patient’s  eyes.  It  may  cause  temporary  vision 

impairment. 

 

3.4 Turn off the power 

Press the power button again to turn off the device.   

 

CAUTION

 

  You must turn off the device to avoid running out of the battery and to save the lifetime of a 

light source (LED). 

 

3.5 Adjust the intensity of light (BT-410A only) 

User can adjust intensity of light using the dial at the bottom side of the “Source of Light Part” by rotating 
the dial CW or CCW. The range of intensity is from 15,000lx to 30,000lx at 25cm working distance. 

Содержание BT-410A

Страница 1: ...BT 410F and BT 410A Head worn light Operation Manual Keep this manual for future reference P N 410 ENG OPM EUR R12...

Страница 2: ...e However no responsibility is assumed by Bistos Corporation For its use or any infringements of patents or other rights of third parties that may result from its use No license is granted by implicat...

Страница 3: ...7 2 1 Product outlook and description 7 2 2 Loupe optional assembly 8 2 3 Astral lamp optional assemble 9 3 Operation 9 3 1 Adjust the headband 9 3 2 Turn on the power 9 3 3 Focusing the light 9 3 4...

Страница 4: ...n product label packaging and this manual in order to stand for the information about Stand by Those symbols identify safety information Warning and caution necessarily well know when operating the de...

Страница 5: ...old environment to a warm humid location Do not attempt to service the BT 410F and BT 410A Only qualified service personnel should attempt any needed internal servicing 0 3 Battery warnings WARNING Do...

Страница 6: ...rief Device Description Product Features Model Configurations 1 2 Brief device description This Head worn light is used for medical examination by fixing it on the head and illuminating with condensed...

Страница 7: ...0A has Fixed Focus lens but BT 410F has Variable focus lens BT 410F and BT 410A system consists of the following function and elements Model BT 410F BT 410A Control of Light Intensity X O Control of L...

Страница 8: ...ration 2 1 Product outlook and description Fig 2 1 BT 410A outlook and description Headband height adjustable part Headband part Headband size adjustable part Protect band Power On Off button LED indi...

Страница 9: ...e shown below Fig 2 3 Loupe Assembly 2 3 Astral lamp optional BT 410A only assembly The astral lamp can be assembled at the bottom of light source Remove the lens cap from the light source and connect...

Страница 10: ...e high charging voltage may cause the device malfunction 3 3 Focusing the light BT 410F only You can adjust the focal length between 25 30 cm Adjust the focus for the best light quality before treatme...

Страница 11: ...r is unseparated When charging unseparated be sure the device turned off To separate or assemble the battery pack refer below Fig 3 1 Battery pack assembly method Fig 3 2 Battery pack separation metho...

Страница 12: ...s during surgery or other cases 4 Maintenance and cleaning 4 1 Checking the light intensity It is recommended that the intensity of the light be checked before each use and at least every six months W...

Страница 13: ...h device or you have further questions please contact Bistos customer center 6 Specifications The BT 410F and BT 410A head worn light is classified as follows in accordance with EN IEC 60601 1 Categor...

Страница 14: ...ons flicker emissions IEC61000 3 3 Complies WARNING The BT 410F and BT 410A should not be used adjacent to or stacked with other equipment If adjacent or stacked use is necessary the device should be...

Страница 15: ...equency magnetic fields should be at levels characteristic of a typical commercial or hospital environment Conducted RF IEC61000 4 6 3 Vrms 150 kHz to 80 MHz 6 Vrms in ISM bands between 0 15 MHz and 8...

Страница 16: ...d with the following symbol IEC 60417 Ref no 5140 Non ionizing electromagnetic radiation Note 1 At 80 MHz and 800 MHz the higher frequency range applies Note 2 These guidelines may not apply in all si...

Страница 17: ...t is manufactured and passed through strict quality control and inspection Compensation standard concerning repair replacement refund of the product complies with Framework Act on Consumers noticed by...

Отзывы: