Содержание Dive Demo Solis

Страница 1: ......

Страница 2: ...er or authorized distributor of our company for a replacement We are constantly researching and improving our Dive Computers and so the product you purchased may differ in certain details from the one...

Страница 3: ...safety given in this manual before diving Danger Before use of this product obtain a C card after completing a proper training program at an internationally recognized diving instruction organization...

Страница 4: ...t resulting in injury or death Do not use this product in a purpose except the recreational diving This product is designed for diving using compressed air 21 of FO2 and Nitrox EANx gas 22 50 of FO2 I...

Страница 5: ...ee months from the last season please use it after checking it Caution Solvents such as gasoline sprays and cleaners such as cosmetic adhesives and paints will adhere to the product and substances suc...

Страница 6: ...you fasten a belt too tightly it becomes easy to sweat and the air does not flow smoothly then it becomes easy to get a rash In normal use please fasten the belt with some room When abnormality occurs...

Страница 7: ...tic parts stick firmly to other products or leave with other products while being wet for long time as it discolors or the color of other products may move to the plastic parts please wipe off water i...

Страница 8: ...ng and the Time Adjusting Home City and Summer Time Setting Watch and Date Setting Dive Mode DIVE Dive Mode No decompression Diving Safety Stop Surface Mode Repetitive Diving Nitrox EANx Diving Dive M...

Страница 9: ...ing Direction Reading COMP Digital Compass Measurement Calibrate a Bearing Sensor Precautions at Digital Compass Measurement Stopwatch STW Enter the Stopwatch Mode Time Measurement Timer TMR Select a...

Страница 10: ...rn the Auto Light Switch On and Off Other Settings Turn the Button Operation Tone On and Off Illumination Duration Setting Turn Power Saving On and Off Unit Setting DISP Screen Setting Troubleshooting...

Страница 11: ...11 NAMES OF PARTS MAIN FUNCTIONS AND SPECIAL FEATURES Buckle Retainer Belt M Button P Button A Button B Button L Button Pressure sensor DIVE DEMO SOLIS...

Страница 12: ...ime signal World Time WT display Display the time of 48 cities 31 time zones of the world Barometric Pressure Indication BARO display Measurement of barometric pressure and temperature Function as wat...

Страница 13: ...ty stop Decompression diving Nitrox Surface Mode TIME 1 and 2 display Desaturation time Surface time Log Mode LOG display Dive log Dive profile Dive history Plan Mode PLAN display Dive plan Fraction o...

Страница 14: ...r 50 Waterproof 100m Log data 30 dives Battery Rechargeable battery Operating time from the full charge condition without the solar generation Approx 1 month 1 one hour dive a day Decompression model...

Страница 15: ...tor Before using this product charge and the setting of the time and date are necessary Please use it after charge it enough and set the display of time and date H lights up M lights up Battery is cha...

Страница 16: ...en the dial gets enough light it generates and charges When you use it please keep it in mind to expose the dial solar panel to light Caution When you charge the product the body may become very hot d...

Страница 17: ...g functions Dive mode Direction reading Light on Sound such as alarm H M L and CHG flashes When H M L and CHG flash together you can use some functions including the indication of the current time Jus...

Страница 18: ...product for diving For example when you start diving in the state of charging level of M and becomes L in the middle of diving the product cannot display the information about the diving In order to...

Страница 19: ...s MODE BEING USED WARNING TO BE DISPLAYED Watch Mode and Surface Mode Letter of CHG flashes Dive Mode The warning continues until the charging level becomes H Meanwhile you cannot use it for diving Wh...

Страница 20: ...time zones in the City Code Table Also select Standard Time or Summer Time DST depending on a country and an area to use the product When you use it in Japan select the city in Tokyo TYO Note The Sum...

Страница 21: ...or L button until it displays the City you need Continue to depress P button or L button for fast forward 3 Depress M button 4 Depress P button and select Summer Time DST setting It switches on and of...

Страница 22: ...CITY for about 1 second after SET Hold flashes 2 Depress M button and select the item to set up Setup item changes by depressing the M button as following order Please do not set the watch and date be...

Страница 23: ...ress A button Setup is completed Note While the 12 hour format is selected P as p m indicator lights up for the times from noon to 11 59 p m With 24 hour format P does not light up Once you set the da...

Страница 24: ...5m for less than 20 seconds When you ascend to the depth of 1 5m WATER deeper than 1 5m for less than 20 seconds When you ascend to the depth of 1 5m WATER Watch Mode Dive Mode No decompression Diving...

Страница 25: ...aximum Depth Screen Direction reading Pagw 28 Pagw 30 Pagw 28 Pagw 28 No decompression Limit Basic Screen Pagw 30 Watch Screen Pagw 29 Pagw 29 A Button No button operation M Button P Button M Button T...

Страница 26: ...immediately please change it manually by depressing B and M buttons at the same time just before diving It keeps the Dive Mode for one minute When no decompression limit becomes less than 3 minutes al...

Страница 27: ...Graph Displays degree of risk of the quantity of nitrogen TLBG accumulated in the body tissue with ten phases Oxygen Accumulation O2 or Displays degree of risk of the quantity of oxygen Partial Pressu...

Страница 28: ...back to the basic screen in 4 seconds automatically You can choose the basic screen with Current Depth as a basic display or the one with No decompression Limit as a basic display Please refer to DI S...

Страница 29: ...in 4 seconds automatically Depress M button to display digital compass reading screen Digital compass reading screen displays the following information Current time Direction Angle value Depress P bu...

Страница 30: ...h screen is displayed for 1 minute After 1 minute it goes back to the basic screen automatically For immediate return to the basic screen please depress L button Seconds Date Time Safety Stop This pro...

Страница 31: ...up 2 Countdown timer is displayed as SAFE 5m 03 00 and 3 minute timer starts Also the timer displays as SAFE 5m 02 30 and SAFE 5m 02 00 every 30 seconds until the last 1 minute and it displays only c...

Страница 32: ...e it displays desaturation time and surface interval time Surface Mode screen displays the following information Desaturation Time DESAT The time when nitrogen accumulated in the body tissue is releas...

Страница 33: ...e body tissue disappear and the screen returns to the Watch Mode the indicator turns on until it passes for 24 hours Warning Never board to airplane in the following states The risk to contract decomp...

Страница 34: ...the fraction of oxygen and the depth in consideration of oxygen poisoning by the excess oxygen absorbed to the body tissue in addition to the normal diving display When it is Nitrox EANx diving the sc...

Страница 35: ...Alarm sounds for 6 seconds 3 After that the screen switches to the Decompression Dive Screen Before Decompression Stop automatically Page 37 4 When you complete the decompression stop at the depth re...

Страница 36: ...2 or Displays degree of risk of the quantity of oxygen Partial Pressure of Oxygen PO2 accumulated in the body or current partial Bar Graph pressure of oxygen with ten phases Displays either one with h...

Страница 37: ...Tissue loading bar graph TLBG Oxygen accumulation O2 or partial pressure of oxygen PO2 bar graph Display position of the decompression stop depth and current depth interchange when you depress the P b...

Страница 38: ...n Before decompression stop in 4 seconds automatically Depress M button to display digital compass reading screen Digital compass reading screen displays the following information Current time Directi...

Страница 39: ...asic screen Before decompression stop please depress L button Date Seconds Time Decompression Dive Under Decompression Stop When you ascend to the decompression stop depth the screen switches to decom...

Страница 40: ...ximum 599 minutes Tissue Loading Bar Graph Displays degree of risk of the quantity of nitrogen TLBG accumulated in the body tissue with ten phases Oxygen Accumulation O2 or Displays degree of risk of...

Страница 41: ...ng bar graph TLBG Oxygen accumulation O2 or partial pressure of oxygen PO2 bar graph Display of the decompression timer switches to the current depth and the current depth to decompression stop depth...

Страница 42: ...on stop in 4 seconds automatically Depress M button to display direction reading screen Direction reading screen displays the following information Current time Direction Angle value Depress P button...

Страница 43: ...information Date Seconds Hour Minutes Watch screen is displayed for 1 minute After 1 minute it goes back to the decompression dive basic screen Under decompression stop automatically For immediate ret...

Страница 44: ...warning of SLO displays in the main portion of the screen and alarm beeps for 3 seconds When the ascent rate becomes the appropriate one the warning of SLO disappears and the warning is canceled When...

Страница 45: ...sounds for 6 seconds 3 It cancels the warning automatically when you return to the depth within the range of the decompression stop depth but continues warning when you do not return If warning occur...

Страница 46: ...mal range If warning occurs even once it will be recorded on dive log High Partial Pressure of Oxygen Alarm High PO2 Alarm The warning activates when the partial pressure of oxygen becomes 1 4 or more...

Страница 47: ...ascent time exceeds 99 minutes while decompression diving 1 E E E E mark lights up in a main display portion 2 Alarm sounds for 3 seconds If warning occurs even once it will be recorded on dive log W...

Страница 48: ...LOG MODE LOG Log Mode Watch Mode Surface Mode A Button L Button P Button M Button for more than 2 seconds 48...

Страница 49: ...ess L button once at the time of Watch Mode or Surface Mode to Log Mode It switches to Log Mode in 1 second after the screen displays LOG It displays the newest log once it switches to Log Mode Depres...

Страница 50: ...during the dive Average depth Average depth during the dive Warning occurred Warning occurred during the dive L 3 Fraction of oxygen used Fraction of oxygen of tank used during the dive Common items T...

Страница 51: ...ation Log No Dive date Dive No Entry time Depress A button to display L 1 screen Alternate display of year month and date Entry Time Log No Dive No L 1 L 1 screen displays the following information Ex...

Страница 52: ...e depth becomes less than the Violation Warning decompression stop depth required while under decompression stop High Partial Pressure PO2 When the partial pressure of oxygen becomes 1 4 of Oxygen Ala...

Страница 53: ...LOG MODE LOG L 3 L 3 screen displays the following information Fraction of oxygen used Depress A button to display PROF screen Fraction of Oxygen Used 53...

Страница 54: ...progress Whenever you depress the L button data is updated at intervals of 30 seconds and the time graph started and the time graph ended return Continue to depress P or L button for fast forward Sinc...

Страница 55: ...Surface Mode LOG is displayed on a screen and it switches to Log Mode in about 1 second The newest log is displayed when it switches to Log Mode 2 Depress L button again HIST is displayed on a screen...

Страница 56: ...nd safety factor etc set at that time No decompression Limit Scheduled Dive Depth Check a Plan Plan Mode 1 Depress P button once at the time of Watch Mode or Surface Mode PLAN is displayed on a screen...

Страница 57: ...about 2 seconds Release the button when SF 0 2 and 21 50 are displayed after SET Hold flashes 3 Every time you depress the M button it is set up as follows SF 0 Default value SF 1 SF 2 4 Depress A bu...

Страница 58: ...nd 32 When you set up to 22 50 Nx mark lights up 4 Depress A button to return to Plan Mode Setup is completed Caution In Nitrox EANx diving you have to set up fraction of oxygen FO2 ratio for every di...

Страница 59: ...moved and calculates the release of residual nitrogen and oxygen by non step automatically it also can be used at high place without any switch operation or a special setup Moreover since depth displa...

Страница 60: ...Compass Measurement It can be used in Watch Mode Surface Mode and Dive Mode Meanings of the Direction Abbreviations Meaning North North northeast Northeast East northeast East East southeast Southeas...

Страница 61: ...cy of measurement please calibrate the bearing sensor before measurement Digital Compass Measurement 61 Calibrate a Bearing Sensor Bidirectional Calibration Please use it when the angle value has shif...

Страница 62: ...s flowing 2 epress L button It starts to calibrate the first direction is shown on the display while calibration is being performed When calibration is successful display shows Turn 180 then CALIBRATI...

Страница 63: ...as a train a ship and an airplane Accurate measurement cannot be performed in a room especially in the building of reinforced concrete construction Place to keep When this product becomes magnetized t...

Страница 64: ...ns to 0 and continues measurement Stopwatch can be used at the time of Watch Mode and Surface Mode When you depress M button twice at the time of Watch Mode or Surface Mode it switches to the Stopwatc...

Страница 65: ...urement Time Measurement To pause at a split time STOPWATCH STW 65 P button Start P button Stop P button Restart P button Stop L button Reset P button Start L button Split L button Reset release L but...

Страница 66: ...ounds for 10 seconds Timer can be used at the time of Watch Mode and Surface Mode When you depress M button three times at the time of Watch Mode or Surface Mode it switches to the Timer Mode TMR is d...

Страница 67: ...hen you set up a timer for 24 hours adjust the display of timer to 0H00 00 4 Depress A button Setting is completed If nothing is operated for 2 to 3 minutes it finishes the setup screen automatically...

Страница 68: ...alarm sounds for about 10 seconds and repeats it 7 times in every 5 minutes You can also turn on an hourly time signal every hour on the hour 00 minutes Minutes Hour P p m Indicator Alarm Indicator C...

Страница 69: ...e 12 hour format it displays P indicator in p m 5 Depress A button Setup is completed Alarm number set up the time becomes ON If nothing is operated for 2 to 3 minutes it finishes the setup screen aut...

Страница 70: ...to stop the alarm Even if it is switched to other displays such as dive mode alarm sounds In the case of snooze alarm when the time reaches the preset alarm time alarm sounds for about 10 seconds and...

Страница 71: ...as to the City Code p 88 Selected World Time City Current Time at the Selected City Current Time Summer Time Indicator Enter the World Time Mode When you depress M button five times at the time of Wa...

Страница 72: ...tton DOWN to select a City Code while in World Time Mode It displays current time of the selected city Continue to depress P button or L button for fast forward Summer Time DST Setting Note The Summer...

Страница 73: ...temperature are displayed in about 1 second It calculates every 5 seconds It performs remeasurement by depressing P button The screen continues to display for 60 minutes Barometric Pressure Display Me...

Страница 74: ...measurement Turn on illumination automatically Auto Light Illumination turns on automatically when you angle the product more than 40 while the Auto Light Switch is on Note The auto light switch does...

Страница 75: ...oduct is more than 15 degree above or below parallel Wearing this product under your sleeve can cause frequent illumination of the display and may run down the battery Static electricity or magnetic f...

Страница 76: ...ation Tone On Off Illumination Duration Power Saving Unit DISP Screen The number expresses the number of times to depress the M button Other than time settings you can change the following settings Bu...

Страница 77: ...CITY for about 1 second after SET Hold flashes 2 Depress M button nine times It enters the screen to select the button operation tone on and off Key or MUTE is displayed 3 Depress P button to select K...

Страница 78: ...n to select 1 1 5 seconds duration or 3 3 seconds duration 4 Depress A button Setting is completed OTHER SETTINGS Turn Power Saving On and Off You can turn power saving on and off 1 While in the Watch...

Страница 79: ...city name are displayed as flowing following the display of CITY for about 1 second after SET Hold flashes 2 Depress M button thirteen times Screen displays DISP and it switches to setup screen in abo...

Страница 80: ...re than 2 seconds Release the button when a City Code and its city name are displayed as flowing following the display of CITY for about 1 second after SET Hold flashes 2 Select any city other than To...

Страница 81: ...since the decompression stop violation warning came out please perform the decompression stop at the depth required again When 10 minutes or more have passed you cannot use the product in diving for...

Страница 82: ...When ERR does not disappear sensor trouble is considered Please consult with your original dealer ERR is displayed after having performed bidirectional calibration If ERR is displayed after showing th...

Страница 83: ...ry power will recover in about 15 minutes Expose the product to bright light for faster recovery Please refer to How to Charge Page 16 Performing multiple sensor in a short period may cause the shorta...

Страница 84: ...with a soft toothbrush by using thinned neutral detergent with water and soapsuds Then please rinse a detergent ingredient well with water and wipe off the water with soft hygroscopic cloth Also when...

Страница 85: ...name your address and telephone number and send it to your original dealer Reserving period of parts Our company reserves the performance parts the parts required to maintain the function of the produ...

Страница 86: ...second Barometric pressure measurement 20 seconds Measuring range Depth 1 5m 99 9m Based on sea water Dive time 0 599 min Operating barometric pressure More than 460 hPa Approx up to 6 000m Temperatu...

Страница 87: ...lar generation Approx 1 month 1 one hour dive a day Decompression model A A Buhlman 16 tissue Altitude diving Barometric pressure linked non step calculation system The system measures the barometric...

Страница 88: ...e you need on the map DATELINE UTC Offset GMT Differential City Code Table City Code City UTC Offset GMT Differential UTC 0 LIS Lisbon 0 LON London 0 MAD Madrid 1 PAR Paris 1 ROM Rome 1 BER Berlin 1 S...

Страница 89: ...DAC Dhaka 6 RGN Yangon 6 5 BKK Bangkok 7 SIN Singapore 8 HKG Hong Kong 8 BJS Beijing 8 TPE Taipei 8 SEL Seoul 9 TYO Tokyo 9 ADL Adelaide 9 5 GUM Guam 10 SYD Sydney 10 NOU Noumea 11 WLG Wellington 12 P...

Страница 90: ...scow has been changed to 4 it does not correspond with this product Please use it by setting summer time DST forward for 1 hour This list is the city code table of this product When the city code to s...

Страница 91: ...91 memo...

Страница 92: ...memo 92...

Страница 93: ...memo 93...

Страница 94: ...memo 94...

Страница 95: ...memo 95...

Страница 96: ...memo 96...

Страница 97: ...memo 97...

Страница 98: ...memo 98...

Страница 99: ...memo 99...

Страница 100: ......

Отзывы: